    Field Test of Magnetic Methods for Corrosion Detection in Prestressing Strands in Adjacent Box-Beam Bridges

    Source: Journal of Bridge Engineering:;2012:;Volume ( 017 ):;issue: 006
    Author:
    Bertrand
    ,
    Fernandes
    ,
    Michael
    ,
    Titus
    ,
    Douglas
    ,
    Karl Nims
    ,
    Al
    ,
    Ghorbanpoor
    ,
    Vijay
    ,
    Devabhaktuni
    DOI: 10.1061/(ASCE)BE.1943-5592.0000379
    Publisher: American Society of Civil Engineers
    Abstract: Magnetic methods are progressing in the detection of corrosion in prestressing strands in adjacent precast, prestressed concrete box-beam bridges. This study is the first field trial of magnetic strand defect detection systems on an adjacent box-beam bridge. A bridge in Fayette County, Ohio, that was scheduled for demolition was inspected. The prestressed box beams had significant strand corrosion. The corroded strands showed discontinuities and a reduced cross-sectional area. These changes are reflected in the magnetic signatures of the prestressing steel. Corrosion in the prestressing steel was detected using two magnetic methods; namely, the magnetic flux leakage method and the induced magnetic field method. The purpose of these tests was to demonstrate the ability of the magnetic methods to detect hidden corrosion in box beams in the field and tackle the logistic problem of inspecting box beams from the bottom. The inspections were validated by dissecting the bottom of the box beams after the inspections. The results showed that the magnetic flux leakage method detects hidden corrosion and strand breaks with a sufficient amount of accuracy. Both magnetic field methods were also able to estimate corrosion by detecting the effective cross-sectional area of the strand. Thus, it was shown that the magnetic methods can be used with sufficient reliability to predict hidden corrosion in prestressing strands of box beams. The recommended actions to make magnetic inspection practical are discussed.
    • Download: (3.001Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Field Test of Magnetic Methods for Corrosion Detection in Prestressing Strands in Adjacent Box-Beam Bridges

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/56925
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorBertrand
    contributor authorFernandes
    contributor authorMichael
    contributor authorTitus
    contributor authorDouglas
    contributor authorKarl Nims
    contributor authorAl
    contributor authorGhorbanpoor
    contributor authorVijay
    contributor authorDevabhaktuni
    date accessioned2017-05-08T21:35:27Z
    date available2017-05-08T21:35:27Z
    date copyrightNovember 2012
    date issued2012
    identifier other%28asce%29be%2E1943-5592%2E0000381.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/56925
    description abstractMagnetic methods are progressing in the detection of corrosion in prestressing strands in adjacent precast, prestressed concrete box-beam bridges. This study is the first field trial of magnetic strand defect detection systems on an adjacent box-beam bridge. A bridge in Fayette County, Ohio, that was scheduled for demolition was inspected. The prestressed box beams had significant strand corrosion. The corroded strands showed discontinuities and a reduced cross-sectional area. These changes are reflected in the magnetic signatures of the prestressing steel. Corrosion in the prestressing steel was detected using two magnetic methods; namely, the magnetic flux leakage method and the induced magnetic field method. The purpose of these tests was to demonstrate the ability of the magnetic methods to detect hidden corrosion in box beams in the field and tackle the logistic problem of inspecting box beams from the bottom. The inspections were validated by dissecting the bottom of the box beams after the inspections. The results showed that the magnetic flux leakage method detects hidden corrosion and strand breaks with a sufficient amount of accuracy. Both magnetic field methods were also able to estimate corrosion by detecting the effective cross-sectional area of the strand. Thus, it was shown that the magnetic methods can be used with sufficient reliability to predict hidden corrosion in prestressing strands of box beams. The recommended actions to make magnetic inspection practical are discussed.
    publisherAmerican Society of Civil Engineers
    titleField Test of Magnetic Methods for Corrosion Detection in Prestressing Strands in Adjacent Box-Beam Bridges
    typeJournal Paper
    journal volume17
    journal issue6
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0000379
    treeJournal of Bridge Engineering:;2012:;Volume ( 017 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian