    Full-Scale Ultimate-Load Test of a Stress-Laminated-Timber Bridge Deck

    Source: Journal of Bridge Engineering:;2012:;Volume ( 017 ):;issue: 004
    Author:
    K. Ekholm
    ,
    R. Kliger
    ,
    R. Crocetti
    DOI: 10.1061/(ASCE)BE.1943-5592.0000304
    Publisher: American Society of Civil Engineers
    Abstract: A general assumption reported in the literature is that the structural response of a stress-laminated-timber (SLT) bridge deck is linear until failure. However, few studies of ultimate-load tests (ULTs) on timber bridges have been reported. A full-scale test of a SLT deck (span, 4.9 m; thickness, 270 mm) was performed to obtain the deformations at various prestress levels as well as at the ultimate-load capacity of such a structure. Prior to the ULT, nondestructive tests (NDT) were performed at three different prestress levels. The load was applied as an axle load positioned both centrically and eccentrically. The deflections were about 10% larger at a prestress level of 300 kPa compared with a prestress level of 600 and 900 kPa. For applied loads larger than 150–250 kN, the deflection of the deck was nonlinear at certain positions. This was most likely owing to large concentrated shear forces that resulted in interlaminar slip between the laminates. The limit for linearity seems to be dependent on the applied prestress. A prestress of 600 kPa and an eccentrically positioned load was used for the ULT. Failure occurred at a load level of 900 kN. The existing design codes and new procedures in development may be verified and calibrated against the results in this paper.
    • Download: (1.540Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Full-Scale Ultimate-Load Test of a Stress-Laminated-Timber Bridge Deck

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/56848
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorK. Ekholm
    contributor authorR. Kliger
    contributor authorR. Crocetti
    date accessioned2017-05-08T21:35:19Z
    date available2017-05-08T21:35:19Z
    date copyrightJuly 2012
    date issued2012
    identifier other%28asce%29be%2E1943-5592%2E0000306.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/56848
    description abstractA general assumption reported in the literature is that the structural response of a stress-laminated-timber (SLT) bridge deck is linear until failure. However, few studies of ultimate-load tests (ULTs) on timber bridges have been reported. A full-scale test of a SLT deck (span, 4.9 m; thickness, 270 mm) was performed to obtain the deformations at various prestress levels as well as at the ultimate-load capacity of such a structure. Prior to the ULT, nondestructive tests (NDT) were performed at three different prestress levels. The load was applied as an axle load positioned both centrically and eccentrically. The deflections were about 10% larger at a prestress level of 300 kPa compared with a prestress level of 600 and 900 kPa. For applied loads larger than 150–250 kN, the deflection of the deck was nonlinear at certain positions. This was most likely owing to large concentrated shear forces that resulted in interlaminar slip between the laminates. The limit for linearity seems to be dependent on the applied prestress. A prestress of 600 kPa and an eccentrically positioned load was used for the ULT. Failure occurred at a load level of 900 kN. The existing design codes and new procedures in development may be verified and calibrated against the results in this paper.
    publisherAmerican Society of Civil Engineers
    titleFull-Scale Ultimate-Load Test of a Stress-Laminated-Timber Bridge Deck
    typeJournal Paper
    journal volume17
    journal issue4
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0000304
    treeJournal of Bridge Engineering:;2012:;Volume ( 017 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian