    Mitigation Methods of Climate Change Impact on the Cooling Load of Public Residential Buildings in Singapore

    Source: Journal of Architectural Engineering:;2013:;Volume ( 019 ):;issue: 003
    Author:
    Nyuk Hien
    ,
    Wong
    ,
    Steve Kardinal
    ,
    Jusuf
    ,
    Nedyomukti Imam
    ,
    Syafii
    ,
    Wen Hui
    ,
    Li
    ,
    Erna
    ,
    Tan
    DOI: 10.1061/(ASCE)AE.1943-5568.0000124
    Publisher: American Society of Civil Engineers
    Abstract: Buildings have time-varying interactions with the local climate condition for the heating or cooling systems; changes of the surrounding climate condition affect building energy consumption. Based on the thermal envelope approach, which considers the heat gain by conduction and radiation through the wall and fenestration, the cooling load simulation study was conducted to see the impact of climate change on the cooling load of public residential buildings in Singapore and propose mitigation methods to bring the predicted increase of the cooling load in the future back to the current level. From the simulation results, climate change is predicted to increase the cooling load of current public residential models for 11.8–55.8% through three different time frames. Based on the parametric study of mitigation methods proposed, changing the material of the wall, material of the glass, and the surface properties show a smaller increase in the predicted cooling load compared with other methods because of the low window to wall ratio. A combination of three methods shows that the increase of the predicted cooling load in Period 3 can be brought back to the current level.
    • Download: (1.580Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Mitigation Methods of Climate Change Impact on the Cooling Load of Public Residential Buildings in Singapore

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/56125
    Collections
    • Journal of Architectural Engineering

    Show full item record

    contributor authorNyuk Hien
    contributor authorWong
    contributor authorSteve Kardinal
    contributor authorJusuf
    contributor authorNedyomukti Imam
    contributor authorSyafii
    contributor authorWen Hui
    contributor authorLi
    contributor authorErna
    contributor authorTan
    date accessioned2017-05-08T21:33:34Z
    date available2017-05-08T21:33:34Z
    date copyrightSeptember 2013
    date issued2013
    identifier other%28asce%29ae%2E1943-5568%2E0000124.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/56125
    description abstractBuildings have time-varying interactions with the local climate condition for the heating or cooling systems; changes of the surrounding climate condition affect building energy consumption. Based on the thermal envelope approach, which considers the heat gain by conduction and radiation through the wall and fenestration, the cooling load simulation study was conducted to see the impact of climate change on the cooling load of public residential buildings in Singapore and propose mitigation methods to bring the predicted increase of the cooling load in the future back to the current level. From the simulation results, climate change is predicted to increase the cooling load of current public residential models for 11.8–55.8% through three different time frames. Based on the parametric study of mitigation methods proposed, changing the material of the wall, material of the glass, and the surface properties show a smaller increase in the predicted cooling load compared with other methods because of the low window to wall ratio. A combination of three methods shows that the increase of the predicted cooling load in Period 3 can be brought back to the current level.
    publisherAmerican Society of Civil Engineers
    titleMitigation Methods of Climate Change Impact on the Cooling Load of Public Residential Buildings in Singapore
    typeJournal Paper
    journal volume19
    journal issue3
    journal titleJournal of Architectural Engineering
    identifier doi10.1061/(ASCE)AE.1943-5568.0000124
    treeJournal of Architectural Engineering:;2013:;Volume ( 019 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace