YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Performance of Axially Loaded Short Rectangular Columns Strengthened with Carbon Fiber-Reinforced Polymer Wrapping

    Source: Journal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 003
    Author:
    Omar Chaallal
    ,
    Mohsen Shahawy
    ,
    Munzer Hassan
    DOI: 10.1061/(ASCE)1090-0268(2003)7:3(200)
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents results of a comprehensive experimental investigation on the behavior of axially loaded short rectangular columns that have been strengthened with carbon fiber-reinforced polymer (CFRP) wrap. Six series, a total of 90 specimens, of uniaxial compression tests were conducted on rectangular and square short columns. The behavior of the specimens in the axial and transverse directions is investigated. The parameters considered in this study are (1) the concrete strength; (2) the aspect ratio of the cross section; and (3) the number of CFRP layers. The findings of this research can be summarized as follows: The CFRP wrapping enhances the compressive strength and the ductility of both square and rectangular columns, but to a lesser degree than that of circular columns. The ultimate strength and the ductility of the CFRP confined concrete increase with increasing number of confining layers. The increase in strength and ductility is more significant for lower strength concrete, representing poor or degraded concrete, than for normal-to-high strength concrete; that is, the maximum gain in strength that can be achieved for 3 ksi concrete wrapped columns is approximately 90%, as compared to only 30% for 6 ksi concrete wrapped columns. The CFRP confining jacket must be sufficiently stiff to develop appropriate confining forces at relatively low axial strain levels. The gain in compressive strength obtained by the CFRP confined concrete depends mainly on the relative stiffness of the CFRP jacket to the axial stiffness of the column.
    • Download: (435.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance of Axially Loaded Short Rectangular Columns Strengthened with Carbon Fiber-Reinforced Polymer Wrapping

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/54188
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorOmar Chaallal
    contributor authorMohsen Shahawy
    contributor authorMunzer Hassan
    date accessioned2017-05-08T21:30:34Z
    date available2017-05-08T21:30:34Z
    date copyrightAugust 2003
    date issued2003
    identifier other%28asce%291090-0268%282003%297%3A3%28200%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54188
    description abstractThis paper presents results of a comprehensive experimental investigation on the behavior of axially loaded short rectangular columns that have been strengthened with carbon fiber-reinforced polymer (CFRP) wrap. Six series, a total of 90 specimens, of uniaxial compression tests were conducted on rectangular and square short columns. The behavior of the specimens in the axial and transverse directions is investigated. The parameters considered in this study are (1) the concrete strength; (2) the aspect ratio of the cross section; and (3) the number of CFRP layers. The findings of this research can be summarized as follows: The CFRP wrapping enhances the compressive strength and the ductility of both square and rectangular columns, but to a lesser degree than that of circular columns. The ultimate strength and the ductility of the CFRP confined concrete increase with increasing number of confining layers. The increase in strength and ductility is more significant for lower strength concrete, representing poor or degraded concrete, than for normal-to-high strength concrete; that is, the maximum gain in strength that can be achieved for 3 ksi concrete wrapped columns is approximately 90%, as compared to only 30% for 6 ksi concrete wrapped columns. The CFRP confining jacket must be sufficiently stiff to develop appropriate confining forces at relatively low axial strain levels. The gain in compressive strength obtained by the CFRP confined concrete depends mainly on the relative stiffness of the CFRP jacket to the axial stiffness of the column.
    publisherAmerican Society of Civil Engineers
    titlePerformance of Axially Loaded Short Rectangular Columns Strengthened with Carbon Fiber-Reinforced Polymer Wrapping
    typeJournal Paper
    journal volume7
    journal issue3
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)1090-0268(2003)7:3(200)
    treeJournal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian