    Archive

    Composite Reinforcement to Strengthen Existing Concrete Structures against Air Blast

    Source: Journal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 002
    Author:
    Larry C. Muszynski
    ,
    Michael R. Purcell
    DOI: 10.1061/(ASCE)1090-0268(2003)7:2(93)
    Publisher: American Society of Civil Engineers
    Abstract: The Wright Laboratory Air Base Survivability Section has been studying the development, application, and effects of externally applied composite reinforcing materials. The strengthened facilities would be capable of surviving an air-blast load at relatively short stand-off distances (11–15 m). An agreement was reached with the Israeli officials to conduct full-scale explosive tests in Israel using 860 kg of TNT on structures that had been reinforced externally with composite reinforcing materials. The strengthening procedure employed in this study involved two types of material: (1) an autoclave-cured, three-ply, carbon fiber-epoxy laminate; and (2) a knitted biaxial E-glass fabric. The Air Base Survivability Section applied the composite materials in Israel after the facilities had been constructed using an epoxy adhesive to bond the composite materials to the concrete substrate. This provided a simple, effective, and quick method of retrofitting an existing structure. The free-field and reflected pressures and accelerations on the walls were measured. The results of these tests were considered successful, considering the fact that the externally reinforced walls suffered high displacements, yet did not fail. The pressure and impulse data indicate that both structures would have failed catastrophically without the externally applied composite reinforcing materials.
    • Download: (52.72Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Composite Reinforcement to Strengthen Existing Concrete Structures against Air Blast

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/54181
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorLarry C. Muszynski
    contributor authorMichael R. Purcell
    date accessioned2017-05-08T21:30:33Z
    date available2017-05-08T21:30:33Z
    date copyrightMay 2003
    date issued2003
    identifier other%28asce%291090-0268%282003%297%3A2%2893%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54181
    description abstractThe Wright Laboratory Air Base Survivability Section has been studying the development, application, and effects of externally applied composite reinforcing materials. The strengthened facilities would be capable of surviving an air-blast load at relatively short stand-off distances (11–15 m). An agreement was reached with the Israeli officials to conduct full-scale explosive tests in Israel using 860 kg of TNT on structures that had been reinforced externally with composite reinforcing materials. The strengthening procedure employed in this study involved two types of material: (1) an autoclave-cured, three-ply, carbon fiber-epoxy laminate; and (2) a knitted biaxial E-glass fabric. The Air Base Survivability Section applied the composite materials in Israel after the facilities had been constructed using an epoxy adhesive to bond the composite materials to the concrete substrate. This provided a simple, effective, and quick method of retrofitting an existing structure. The free-field and reflected pressures and accelerations on the walls were measured. The results of these tests were considered successful, considering the fact that the externally reinforced walls suffered high displacements, yet did not fail. The pressure and impulse data indicate that both structures would have failed catastrophically without the externally applied composite reinforcing materials.
    publisherAmerican Society of Civil Engineers
    titleComposite Reinforcement to Strengthen Existing Concrete Structures against Air Blast
    typeJournal Paper
    journal volume7
    journal issue2
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)1090-0268(2003)7:2(93)
    treeJournal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian