    Quality Assurance of GFRP Pipes for Seawater Cooling of Power Plants

    Source: Journal of Composites for Construction:;1999:;Volume ( 003 ):;issue: 001
    Author:
    O. Ishai
    ,
    J. M. Lifshitz
    DOI: 10.1061/(ASCE)1090-0268(1999)3:1(27)
    Publisher: American Society of Civil Engineers
    Abstract: Many electrical power plants are located along coastlines and use seawater for cooling purposes. The traditional material for the pipes was, until not so long ago, steel that posed severe maintenance problems due to corrosion and accumulation of sediment on its surface. In the last three decades glass fiber reinforced polyester (GFRP)-pipes of various compositions replaced some steel pipes, mainly for being corrosion free and easy to maintain. This advantage of the GFRP pipes is offset by their low stiffness, complicated design and testing procedure before and during production, and higher cost. A joint project with the Agricultural Engineering Department to design and test large-diameter GFRP pipes began at the Composite Mechanics Laboratory, Technion–Israel Institute of Technology, in 1978. The present paper addresses some of the problems and the experience accumulated over the years. Based on the long-term service experience, it is suggested that four tests are sufficient for the full assessment and certification of the respective main composite pipe characteristics, namely, hoop stiffness, hoop strength, longitudinal strength, and interlaminar shear strength. The first three are required for the proper performance of the pipe and its resistance to fracture and buckling. The last (interlaminar) property is an important indicator of interlaminar integrity of the pipe, to ensure proper fabrication procedure.
    • Download: (2.205Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Quality Assurance of GFRP Pipes for Seawater Cooling of Power Plants

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/54021
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorO. Ishai
    contributor authorJ. M. Lifshitz
    date accessioned2017-05-08T21:30:19Z
    date available2017-05-08T21:30:19Z
    date copyrightFebruary 1999
    date issued1999
    identifier other%28asce%291090-0268%281999%293%3A1%2827%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54021
    description abstractMany electrical power plants are located along coastlines and use seawater for cooling purposes. The traditional material for the pipes was, until not so long ago, steel that posed severe maintenance problems due to corrosion and accumulation of sediment on its surface. In the last three decades glass fiber reinforced polyester (GFRP)-pipes of various compositions replaced some steel pipes, mainly for being corrosion free and easy to maintain. This advantage of the GFRP pipes is offset by their low stiffness, complicated design and testing procedure before and during production, and higher cost. A joint project with the Agricultural Engineering Department to design and test large-diameter GFRP pipes began at the Composite Mechanics Laboratory, Technion–Israel Institute of Technology, in 1978. The present paper addresses some of the problems and the experience accumulated over the years. Based on the long-term service experience, it is suggested that four tests are sufficient for the full assessment and certification of the respective main composite pipe characteristics, namely, hoop stiffness, hoop strength, longitudinal strength, and interlaminar shear strength. The first three are required for the proper performance of the pipe and its resistance to fracture and buckling. The last (interlaminar) property is an important indicator of interlaminar integrity of the pipe, to ensure proper fabrication procedure.
    publisherAmerican Society of Civil Engineers
    titleQuality Assurance of GFRP Pipes for Seawater Cooling of Power Plants
    typeJournal Paper
    journal volume3
    journal issue1
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)1090-0268(1999)3:1(27)
    treeJournal of Composites for Construction:;1999:;Volume ( 003 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace