    Archive

    VOC Ground-Water Sampling Decontamination Procedures: A Case Study

    Source: Practice Periodical of Hazardous, Toxic, and Radioactive Waste Management:;1998:;Volume ( 002 ):;issue: 002
    Author:
    Mark Marlowe
    ,
    David Preston
    ,
    Charles Steffens
    ,
    Charles H. McPherson Jr.
    DOI: 10.1061/(ASCE)1090-025X(1998)2:2(62)
    Publisher: American Society of Civil Engineers
    Abstract: A case study is presented where acetone was detected in ground water at a site even though acetone was neither used by the current or previous facility operators nor during ground-water sampling for volatile organic compounds. Sampling and decontamination procedures followed recommended U.S. Environmental Protection Agency (USEPA) decontamination procedures. The only organic solvent used during field decontamination procedures was pesticide grade isopropanol. Acetone was detected in the pesticide grade isopropanol used during the field activities. Investigation of the chemistry of isopropanol and acetone indicated that isopropanol can be oxidized to acetone. The results of a controlled test showed that isopropanol and acetone can be introduced into a ground-water monitoring well via decontaminated sampling equipment even after residual decontamination reagent is allowed to air dry in accordance with USEPA procedures. It is concluded that standard decontamination procedures can introduce regulated substances into the ground water. Decontamination procedures should be continuously reviewed and updated, designed for specific sites, and evaluated by skilled professionals based on analytical results obtained for a site. The use of pesticide grade isopropanol for decontamination at sites where acetone is a constituent of concern should be avoided altogether.
    • Download: (409.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      VOC Ground-Water Sampling Decontamination Procedures: A Case Study

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/53557
    Collections
    • Practice Periodical of Hazardous, Toxic, and Radioactive Waste Management

    Show full item record

    contributor authorMark Marlowe
    contributor authorDavid Preston
    contributor authorCharles Steffens
    contributor authorCharles H. McPherson Jr.
    date accessioned2017-05-08T21:29:35Z
    date available2017-05-08T21:29:35Z
    date copyrightApril 1998
    date issued1998
    identifier other%28asce%291090-025x%281998%292%3A2%2862%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/53557
    description abstractA case study is presented where acetone was detected in ground water at a site even though acetone was neither used by the current or previous facility operators nor during ground-water sampling for volatile organic compounds. Sampling and decontamination procedures followed recommended U.S. Environmental Protection Agency (USEPA) decontamination procedures. The only organic solvent used during field decontamination procedures was pesticide grade isopropanol. Acetone was detected in the pesticide grade isopropanol used during the field activities. Investigation of the chemistry of isopropanol and acetone indicated that isopropanol can be oxidized to acetone. The results of a controlled test showed that isopropanol and acetone can be introduced into a ground-water monitoring well via decontaminated sampling equipment even after residual decontamination reagent is allowed to air dry in accordance with USEPA procedures. It is concluded that standard decontamination procedures can introduce regulated substances into the ground water. Decontamination procedures should be continuously reviewed and updated, designed for specific sites, and evaluated by skilled professionals based on analytical results obtained for a site. The use of pesticide grade isopropanol for decontamination at sites where acetone is a constituent of concern should be avoided altogether.
    publisherAmerican Society of Civil Engineers
    titleVOC Ground-Water Sampling Decontamination Procedures: A Case Study
    typeJournal Paper
    journal volume2
    journal issue2
    journal titlePractice Periodical of Hazardous, Toxic, and Radioactive Waste Management
    identifier doi10.1061/(ASCE)1090-025X(1998)2:2(62)
    treePractice Periodical of Hazardous, Toxic, and Radioactive Waste Management:;1998:;Volume ( 002 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian