Releveling and Behavior of Strap-Retrofitted Damaged Test Foundations Exposed to Mine SubsidenceSource: Journal of Geotechnical and Geoenvironmental Engineering:;1997:;Volume ( 123 ):;issue: 009Author:Gennaro G. Marino
DOI: 10.1061/(ASCE)1090-0241(1997)123:9(847)Publisher: American Society of Civil Engineers
Abstract: Test foundation walls were constructed in an area of planned subsidence. These crawl space-sized block bearing walls were located in the tension zone of a longwall panel. The test walls were 12.2 m (40 ft) long and were vertically loaded on top with soil bins to simulate the weight of a house. As the longwall proceeded past these test foundations, subsidence movements damaged the test structures. These damaged foundations were then structurally and aesthetically repaired by using a steel strap retrofit and applying a cementitious surface coating. The repaired test foundations underwent significant subsequent subsidence as an adjacent longwall was mined beneath. The response of the repaired foundation is summarized in this paper. The steel straps were also used to relevel another set of the test foundations after they were tilted and damaged by subsidence. First, the straps were applied to the block bearing walls, and then wall jacks were used to lift the upper portion of the walls to a level position. This releveling procedure is outlined with the results.
|
Show full item record
| contributor author | Gennaro G. Marino | |
| date accessioned | 2017-05-08T21:26:13Z | |
| date available | 2017-05-08T21:26:13Z | |
| date copyright | September 1997 | |
| date issued | 1997 | |
| identifier other | %28asce%291090-0241%281997%29123%3A9%28847%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/51408 | |
| description abstract | Test foundation walls were constructed in an area of planned subsidence. These crawl space-sized block bearing walls were located in the tension zone of a longwall panel. The test walls were 12.2 m (40 ft) long and were vertically loaded on top with soil bins to simulate the weight of a house. As the longwall proceeded past these test foundations, subsidence movements damaged the test structures. These damaged foundations were then structurally and aesthetically repaired by using a steel strap retrofit and applying a cementitious surface coating. The repaired test foundations underwent significant subsequent subsidence as an adjacent longwall was mined beneath. The response of the repaired foundation is summarized in this paper. The steel straps were also used to relevel another set of the test foundations after they were tilted and damaged by subsidence. First, the straps were applied to the block bearing walls, and then wall jacks were used to lift the upper portion of the walls to a level position. This releveling procedure is outlined with the results. | |
| publisher | American Society of Civil Engineers | |
| title | Releveling and Behavior of Strap-Retrofitted Damaged Test Foundations Exposed to Mine Subsidence | |
| type | Journal Paper | |
| journal volume | 123 | |
| journal issue | 9 | |
| journal title | Journal of Geotechnical and Geoenvironmental Engineering | |
| identifier doi | 10.1061/(ASCE)1090-0241(1997)123:9(847) | |
| tree | Journal of Geotechnical and Geoenvironmental Engineering:;1997:;Volume ( 123 ):;issue: 009 | |
| contenttype | Fulltext |