YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Performance Evaluation through Field Testing of Century-Old Railroad Truss Bridge

    Source: Journal of Bridge Engineering:;2008:;Volume ( 013 ):;issue: 002
    Author:
    Michael R. DelGrego
    ,
    Michael P. Culmo
    ,
    John T. DeWolf
    DOI: 10.1061/(ASCE)1084-0702(2008)13:2(132)
    Publisher: American Society of Civil Engineers
    Abstract: Research has been carried out to evaluate the structural behavior and influence of aging on a century-old steel railroad truss bridge. The structure is located in Connecticut and services a large number of trains traveling into and out of New York City. The trusses are made of built-up members, with either multiple eyebars or laced channel sections. All panel point connections are joined with true pins and the interior panels are indeterminate. The bridge had experienced problems relating to the lateral shifting of some of the middepth pins. This study was carried out to evaluate the structural behavior and live load distribution throughout the bridge. A major component of the research involved extensive field monitoring. The results show that the actual live load distribution is significantly different than expected from conventional analytical approaches that were most likely used in the original design. The load distribution in multiple eyebar elements is far from uniform, and the distribution of shear through indeterminate panels is significantly different than expected from a normal truss analysis. Significant out-of-plane bending was found in the truss due to floorbeam end rotations, which is thought to be the major factor that is causing the pins to move. The study shows the necessity of using field monitoring to better understand the behavior of older bridges prior to the design of renovation approaches.
    • Download: (955.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance Evaluation through Field Testing of Century-Old Railroad Truss Bridge

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/51105
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorMichael R. DelGrego
    contributor authorMichael P. Culmo
    contributor authorJohn T. DeWolf
    date accessioned2017-05-08T21:25:43Z
    date available2017-05-08T21:25:43Z
    date copyrightMarch 2008
    date issued2008
    identifier other%28asce%291084-0702%282008%2913%3A2%28132%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/51105
    description abstractResearch has been carried out to evaluate the structural behavior and influence of aging on a century-old steel railroad truss bridge. The structure is located in Connecticut and services a large number of trains traveling into and out of New York City. The trusses are made of built-up members, with either multiple eyebars or laced channel sections. All panel point connections are joined with true pins and the interior panels are indeterminate. The bridge had experienced problems relating to the lateral shifting of some of the middepth pins. This study was carried out to evaluate the structural behavior and live load distribution throughout the bridge. A major component of the research involved extensive field monitoring. The results show that the actual live load distribution is significantly different than expected from conventional analytical approaches that were most likely used in the original design. The load distribution in multiple eyebar elements is far from uniform, and the distribution of shear through indeterminate panels is significantly different than expected from a normal truss analysis. Significant out-of-plane bending was found in the truss due to floorbeam end rotations, which is thought to be the major factor that is causing the pins to move. The study shows the necessity of using field monitoring to better understand the behavior of older bridges prior to the design of renovation approaches.
    publisherAmerican Society of Civil Engineers
    titlePerformance Evaluation through Field Testing of Century-Old Railroad Truss Bridge
    typeJournal Paper
    journal volume13
    journal issue2
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)1084-0702(2008)13:2(132)
    treeJournal of Bridge Engineering:;2008:;Volume ( 013 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian