    Archive

    Overlay for Concrete Segmental Box-Girder Bridges

    Source: Journal of Bridge Engineering:;2000:;Volume ( 005 ):;issue: 004
    Author:
    Fang-Fu Tang
    DOI: 10.1061/(ASCE)1084-0702(2000)5:4(311)
    Publisher: American Society of Civil Engineers
    Abstract: Concrete overlay cracking and delamination were noticed on a concrete segmental box-girder bridge. Analytical investigation and field and laboratory examinations were conducted to identify the major factors causing the defects. The time-dependent stress distribution and its change in the overlay and along the interface between the overlay and the bridge deck were modeled through the finite-element method with the consideration of concrete age, shrinkage, and critical temperature gradients. Appropriate interpretation of the modeling results were verified through field and laboratory examinations. The primary factors causing the defects were identified and discussed. It was concluded that conventional concrete is applicable for a thin bonded overlay construction on concrete segmental box-girder bridges. Removal and replacement were recommended to repair the delaminations through a field test program. Low shrink conventional concrete with a maximum aggregate size of 25.4 mm (1.0 in.) was used without the application of bonding grout. The base deck surface was roughened (by hydroblasting) to a macrotexture of 2.0–2.8 mm (0.08–0.11 in.) on average. The substrata was not presoaked and was surface dry before placing of plastic concrete. Curing consisted of moist curing for 7 days, followed by chemical (curing compound) curing for 21 days. The successful experience gained can be applied to other similar projects.
    • Download: (852.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Overlay for Concrete Segmental Box-Girder Bridges

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/50510
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorFang-Fu Tang
    date accessioned2017-05-08T21:24:48Z
    date available2017-05-08T21:24:48Z
    date copyrightNovember 2000
    date issued2000
    identifier other%28asce%291084-0702%282000%295%3A4%28311%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/50510
    description abstractConcrete overlay cracking and delamination were noticed on a concrete segmental box-girder bridge. Analytical investigation and field and laboratory examinations were conducted to identify the major factors causing the defects. The time-dependent stress distribution and its change in the overlay and along the interface between the overlay and the bridge deck were modeled through the finite-element method with the consideration of concrete age, shrinkage, and critical temperature gradients. Appropriate interpretation of the modeling results were verified through field and laboratory examinations. The primary factors causing the defects were identified and discussed. It was concluded that conventional concrete is applicable for a thin bonded overlay construction on concrete segmental box-girder bridges. Removal and replacement were recommended to repair the delaminations through a field test program. Low shrink conventional concrete with a maximum aggregate size of 25.4 mm (1.0 in.) was used without the application of bonding grout. The base deck surface was roughened (by hydroblasting) to a macrotexture of 2.0–2.8 mm (0.08–0.11 in.) on average. The substrata was not presoaked and was surface dry before placing of plastic concrete. Curing consisted of moist curing for 7 days, followed by chemical (curing compound) curing for 21 days. The successful experience gained can be applied to other similar projects.
    publisherAmerican Society of Civil Engineers
    titleOverlay for Concrete Segmental Box-Girder Bridges
    typeJournal Paper
    journal volume5
    journal issue4
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)1084-0702(2000)5:4(311)
    treeJournal of Bridge Engineering:;2000:;Volume ( 005 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace