    Archive

    Seismic and Wind Load Considerations for Temporary Structures

    Source: Practice Periodical on Structural Design and Construction:;2008:;Volume ( 013 ):;issue: 003
    Author:
    Jamshid Mohammadi
    ,
    Amir Zamani Heydari
    DOI: 10.1061/(ASCE)1084-0680(2008)13:3(128)
    Publisher: American Society of Civil Engineers
    Abstract: Temporary structures such as scaffolds, shelters, tents, and facilities used during the reconstruction or repair of buildings and bridges, etc., are usually constructed for a limited-time use. Although the design of such structures to dead and live loads usually does not impose any particular challenge, their design for potential seismic or wind load requires more careful investigation. This is due to the fact that the service life of a temporary structure is much shorter than a “permanent structure,” and as such, the probability of load exposure to the temporary structure is substantially less. Designing a temporary structure for the same level of seismic load exposure probability than that required for a permanent structure will not be economically viable. Seemingly, it will make sense to use a reduced design load—a level proportional to the intended service life of the structure. Using a reduced load may be a reasonable assumption for a structure that is used once. However, if the decision is to reuse the structure and to keep it for a longer time than was originally intended, a question arises as to whether, with the extended usage, the safety of the structure will be compromised. This paper provides a review of available studies on seismic and wind loads for temporary structures. Further, the use of a modified risk level, estimated based on the performance record of the structure in its initial usage cycle, is suggested. This modified risk can then be employed in making a decision on whether to allow the structure to be used longer. A simple illustrative example and several conclusions are then presented in an effort to open discussions among the structural engineering community to further elaborate on the issue of design loads for temporary structures.
    • Download: (131.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Seismic and Wind Load Considerations for Temporary Structures

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/49296
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorJamshid Mohammadi
    contributor authorAmir Zamani Heydari
    date accessioned2017-05-08T21:23:00Z
    date available2017-05-08T21:23:00Z
    date copyrightAugust 2008
    date issued2008
    identifier other%28asce%291084-0680%282008%2913%3A3%28128%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/49296
    description abstractTemporary structures such as scaffolds, shelters, tents, and facilities used during the reconstruction or repair of buildings and bridges, etc., are usually constructed for a limited-time use. Although the design of such structures to dead and live loads usually does not impose any particular challenge, their design for potential seismic or wind load requires more careful investigation. This is due to the fact that the service life of a temporary structure is much shorter than a “permanent structure,” and as such, the probability of load exposure to the temporary structure is substantially less. Designing a temporary structure for the same level of seismic load exposure probability than that required for a permanent structure will not be economically viable. Seemingly, it will make sense to use a reduced design load—a level proportional to the intended service life of the structure. Using a reduced load may be a reasonable assumption for a structure that is used once. However, if the decision is to reuse the structure and to keep it for a longer time than was originally intended, a question arises as to whether, with the extended usage, the safety of the structure will be compromised. This paper provides a review of available studies on seismic and wind loads for temporary structures. Further, the use of a modified risk level, estimated based on the performance record of the structure in its initial usage cycle, is suggested. This modified risk can then be employed in making a decision on whether to allow the structure to be used longer. A simple illustrative example and several conclusions are then presented in an effort to open discussions among the structural engineering community to further elaborate on the issue of design loads for temporary structures.
    publisherAmerican Society of Civil Engineers
    titleSeismic and Wind Load Considerations for Temporary Structures
    typeJournal Paper
    journal volume13
    journal issue3
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/(ASCE)1084-0680(2008)13:3(128)
    treePractice Periodical on Structural Design and Construction:;2008:;Volume ( 013 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian