    Extreme Wind Design of Self-Supported Steel Structures: Critical Review of Related ASCE Publications

    Source: Practice Periodical on Structural Design and Construction:;2003:;Volume ( 008 ):;issue: 002
    Author:
    Mehran Keshavarzian
    DOI: 10.1061/(ASCE)1084-0680(2003)8:2(102)
    Publisher: American Society of Civil Engineers
    Abstract: Depending on the application, self-supported tubular steel pole (cantilever) structures in the United States are designed for extreme wind loadings based on either ASCE 74 (for electric utility applications), ANSI/TIA/EIA 222 (for antenna applications), AASHTO (for highway sign and traffic signal applications), or ASCE 7 (for general applications, such as stadium billboards). This paper compares the margins of safety of self-supported tubular steel structures designed for extreme wind loadings based on ASCE 74, TIA/EIA, AASHTO and ASCE 7. Based on this comparison, a critical review of the ASCE publications and their respective design requirements and safety factors are presented.
    • Download: (59.05Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Extreme Wind Design of Self-Supported Steel Structures: Critical Review of Related ASCE Publications

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/49080
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorMehran Keshavarzian
    date accessioned2017-05-08T21:22:42Z
    date available2017-05-08T21:22:42Z
    date copyrightMay 2003
    date issued2003
    identifier other%28asce%291084-0680%282003%298%3A2%28102%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/49080
    description abstractDepending on the application, self-supported tubular steel pole (cantilever) structures in the United States are designed for extreme wind loadings based on either ASCE 74 (for electric utility applications), ANSI/TIA/EIA 222 (for antenna applications), AASHTO (for highway sign and traffic signal applications), or ASCE 7 (for general applications, such as stadium billboards). This paper compares the margins of safety of self-supported tubular steel structures designed for extreme wind loadings based on ASCE 74, TIA/EIA, AASHTO and ASCE 7. Based on this comparison, a critical review of the ASCE publications and their respective design requirements and safety factors are presented.
    publisherAmerican Society of Civil Engineers
    titleExtreme Wind Design of Self-Supported Steel Structures: Critical Review of Related ASCE Publications
    typeJournal Paper
    journal volume8
    journal issue2
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/(ASCE)1084-0680(2003)8:2(102)
    treePractice Periodical on Structural Design and Construction:;2003:;Volume ( 008 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian