    Thermal and Economic Evaluation of Slab-on-Grade Insulation in Wood-Framed Buildings

    Source: Journal of Architectural Engineering:;2009:;Volume ( 015 ):;issue: 001
    Author:
    Brian A. Rock
    DOI: 10.1061/(ASCE)1076-0431(2009)15:1(14)
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents a new one-equation model, and case studies utilizing it, for evaluating the thermal effectiveness of slab-on-grade perimeter insulation in common wood-framed buildings for any time period such as a month, a season, or an entire year. Many previous studies focused on heat losses in very cold climates, but this new model can be effective for both heating and cooling in potentially any climate that has coefficients available. Two case studies, of residential and commercial buildings, are presented in this paper for three levels of foundation insulation and for three different, somewhat-warm to somewhat-cold, climates. Economic analyses of their heating seasons, cooling seasons, and annual performance are then presented, and the overall worthiness of the insulation, from energy cost and other perspectives, is discussed. The hand calculation method presented differs from previous efforts because it uses a new, single transient analytical equation and site-specific coefficients. The model gives designers, builders, and code officials, for example, the specific, defensible information needed to make decisions on whether insulation is needed. For the residential and commercial building examples presented at least a minimal amount of perimeter insulation is justified, both thermally and economically, for at least two of the three locations studied.
    • Download: (267.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Thermal and Economic Evaluation of Slab-on-Grade Insulation in Wood-Framed Buildings

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/48811
    Collections
    • Journal of Architectural Engineering

    Show full item record

    contributor authorBrian A. Rock
    date accessioned2017-05-08T21:22:17Z
    date available2017-05-08T21:22:17Z
    date copyrightMarch 2009
    date issued2009
    identifier other%28asce%291076-0431%282009%2915%3A1%2814%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48811
    description abstractThis paper presents a new one-equation model, and case studies utilizing it, for evaluating the thermal effectiveness of slab-on-grade perimeter insulation in common wood-framed buildings for any time period such as a month, a season, or an entire year. Many previous studies focused on heat losses in very cold climates, but this new model can be effective for both heating and cooling in potentially any climate that has coefficients available. Two case studies, of residential and commercial buildings, are presented in this paper for three levels of foundation insulation and for three different, somewhat-warm to somewhat-cold, climates. Economic analyses of their heating seasons, cooling seasons, and annual performance are then presented, and the overall worthiness of the insulation, from energy cost and other perspectives, is discussed. The hand calculation method presented differs from previous efforts because it uses a new, single transient analytical equation and site-specific coefficients. The model gives designers, builders, and code officials, for example, the specific, defensible information needed to make decisions on whether insulation is needed. For the residential and commercial building examples presented at least a minimal amount of perimeter insulation is justified, both thermally and economically, for at least two of the three locations studied.
    publisherAmerican Society of Civil Engineers
    titleThermal and Economic Evaluation of Slab-on-Grade Insulation in Wood-Framed Buildings
    typeJournal Paper
    journal volume15
    journal issue1
    journal titleJournal of Architectural Engineering
    identifier doi10.1061/(ASCE)1076-0431(2009)15:1(14)
    treeJournal of Architectural Engineering:;2009:;Volume ( 015 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace