    Pilot Study for the Performance of a New Demand Control Ventilation System in Hong Kong

    Source: Journal of Architectural Engineering:;2005:;Volume ( 011 ):;issue: 003
    Author:
    Kwok-Wai Mui
    ,
    Wai-Tin Chan
    DOI: 10.1061/(ASCE)1076-0431(2005)11:3(110)
    Publisher: American Society of Civil Engineers
    Abstract: There are different ventilation control methods for outdoor air quantity in air-conditioned spaces to reduce the energy consumed in cooling the outdoor air. Demand controlled ventilation (DCV) is an important strategy to control the outdoor air quantity. However, the current practice in DCV systems creates several problems for air-conditioned office buildings. Although metabolic carbon dioxide
    • Download: (254.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Pilot Study for the Performance of a New Demand Control Ventilation System in Hong Kong

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/48718
    Collections
    • Journal of Architectural Engineering

    Show full item record

    contributor authorKwok-Wai Mui
    contributor authorWai-Tin Chan
    date accessioned2017-05-08T21:22:07Z
    date available2017-05-08T21:22:07Z
    date copyrightSeptember 2005
    date issued2005
    identifier other%28asce%291076-0431%282005%2911%3A3%28110%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48718
    description abstractThere are different ventilation control methods for outdoor air quantity in air-conditioned spaces to reduce the energy consumed in cooling the outdoor air. Demand controlled ventilation (DCV) is an important strategy to control the outdoor air quantity. However, the current practice in DCV systems creates several problems for air-conditioned office buildings. Although metabolic carbon dioxide
    publisherAmerican Society of Civil Engineers
    titlePilot Study for the Performance of a New Demand Control Ventilation System in Hong Kong
    typeJournal Paper
    journal volume11
    journal issue3
    journal titleJournal of Architectural Engineering
    identifier doi10.1061/(ASCE)1076-0431(2005)11:3(110)
    treeJournal of Architectural Engineering:;2005:;Volume ( 011 ):;issue: 003
    contenttypeFulltext