Improving Indoor Air Quality by Increased Ventilation EffectivenessSource: Journal of Architectural Engineering:;1999:;Volume ( 005 ):;issue: 001Author:Peter Rojeski Jr
DOI: 10.1061/(ASCE)1076-0431(1999)5:1(25)Publisher: American Society of Civil Engineers
Abstract: This paper presents the results of an air quality study conducted in a restaurant that allows smoking. Air quality data was taken in the smoking section with a conventional air distribution system in place. The air distribution system was then modified and additional data was taken. Air sample results indicate that the “air curtain” distribution system improves the effectiveness of the ventilation by reducing smoke plume drift between tables and by enhancing the natural tendency of the tobacco smoke to rise to the ceiling. The modifications to the air distribution system included replacing and relocating supply air diffusers and relocating and adding return air grilles over the smokers' tables. Small 100 mm
|
Collections
Show full item record
| contributor author | Peter Rojeski Jr | |
| date accessioned | 2017-05-08T21:21:52Z | |
| date available | 2017-05-08T21:21:52Z | |
| date copyright | March 1999 | |
| date issued | 1999 | |
| identifier other | %28asce%291076-0431%281999%295%3A1%2825%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/48560 | |
| description abstract | This paper presents the results of an air quality study conducted in a restaurant that allows smoking. Air quality data was taken in the smoking section with a conventional air distribution system in place. The air distribution system was then modified and additional data was taken. Air sample results indicate that the “air curtain” distribution system improves the effectiveness of the ventilation by reducing smoke plume drift between tables and by enhancing the natural tendency of the tobacco smoke to rise to the ceiling. The modifications to the air distribution system included replacing and relocating supply air diffusers and relocating and adding return air grilles over the smokers' tables. Small 100 mm | |
| publisher | American Society of Civil Engineers | |
| title | Improving Indoor Air Quality by Increased Ventilation Effectiveness | |
| type | Journal Paper | |
| journal volume | 5 | |
| journal issue | 1 | |
| journal title | Journal of Architectural Engineering | |
| identifier doi | 10.1061/(ASCE)1076-0431(1999)5:1(25) | |
| tree | Journal of Architectural Engineering:;1999:;Volume ( 005 ):;issue: 001 | |
| contenttype | Fulltext |