    Clay Brick Masonry Weight Variation

    Source: Journal of Architectural Engineering:;1996:;Volume ( 002 ):;issue: 004
    Author:
    Clayford T. Grimm
    DOI: 10.1061/(ASCE)1076-0431(1996)2:4(135)
    Publisher: American Society of Civil Engineers
    Abstract: The weight of clay brick masonry can vary by more than 30% from the minimum design dead load required by ASCE 7–95 (“Minimum” 1996). Variations in clay brick masonry weight have implications not only for structural and acoustical design, but also for design of heating, ventilating, and air conditioning systems. Incorrect assumptions about wall weight can result in excessive or inadequate seismic loads on masonry walls; insufficient resistance to uplift; increased structural framing and foundation costs; reduced factors of safety in shear walls; increased summer air conditioning costs; overestimates of acoustical transmission loss; and inefficiency in passive heating and cooling systems. Errors in wall weight estimates can penalize those who choose to build with masonry. Designers should be aware that masonry wall weight is variable and should take that variability into consideration where appropriate.
    • Download: (248.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Clay Brick Masonry Weight Variation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/48495
    Collections
    • Journal of Architectural Engineering

    Show full item record

    contributor authorClayford T. Grimm
    date accessioned2017-05-08T21:21:47Z
    date available2017-05-08T21:21:47Z
    date copyrightDecember 1996
    date issued1996
    identifier other%28asce%291076-0431%281996%292%3A4%28135%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48495
    description abstractThe weight of clay brick masonry can vary by more than 30% from the minimum design dead load required by ASCE 7–95 (“Minimum” 1996). Variations in clay brick masonry weight have implications not only for structural and acoustical design, but also for design of heating, ventilating, and air conditioning systems. Incorrect assumptions about wall weight can result in excessive or inadequate seismic loads on masonry walls; insufficient resistance to uplift; increased structural framing and foundation costs; reduced factors of safety in shear walls; increased summer air conditioning costs; overestimates of acoustical transmission loss; and inefficiency in passive heating and cooling systems. Errors in wall weight estimates can penalize those who choose to build with masonry. Designers should be aware that masonry wall weight is variable and should take that variability into consideration where appropriate.
    publisherAmerican Society of Civil Engineers
    titleClay Brick Masonry Weight Variation
    typeJournal Paper
    journal volume2
    journal issue4
    journal titleJournal of Architectural Engineering
    identifier doi10.1061/(ASCE)1076-0431(1996)2:4(135)
    treeJournal of Architectural Engineering:;1996:;Volume ( 002 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace