YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Infrastructure Systems
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Infrastructure Systems
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Life-Cycle Energy Analysis of a Water Distribution System

    Source: Journal of Infrastructure Systems:;2004:;Volume ( 010 ):;issue: 003
    Author:
    Yves R. Filion
    ,
    Heather L. MacLean
    ,
    Bryan W. Karney
    DOI: 10.1061/(ASCE)1076-0342(2004)10:3(119)
    Publisher: American Society of Civil Engineers
    Abstract: The paper presents a life-cycle energy analysis (LCEA) to quantify energy expenditures in the fabrication, use, and end-of-life stages of the pipes of a water distribution system. The methodology incorporates the capabilities of environmental input-output life-cycle analysis to quantify the energy required to fabricate pipes. The EPANET2 hydraulic model is applied in conjunction with a pipe-aging model to calculate the theoretical energy recovery in the use stage. An exponential pipe-break model is applied to quantify the energy required to repair pipe breaks during the use stage of a system. Simple formulations are developed to estimate the energy required to dispose of and recycle pipes once their service period has expired. The LCEA methodology is then applied to the New York City (NYC) water supply tunnels example to quantify energy expenditures in four planning scenarios with 10-, 20-, 50-, and 100-year pipe replacement frequencies. The results of the NYC example highlight the tension between the energy costs incurred in the fabrication and end-of-life stages of a system and those incurred in the use stage. A pipe-replacement period roughly equal to 50 years yielded the lowest overall energy expenditure in the three life stages. A sensitivity analysis was carried out to assess the influence of uncertain system parameters on energy expenditure estimates.
    • Download: (373.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Life-Cycle Energy Analysis of a Water Distribution System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/48204
    Collections
    • Journal of Infrastructure Systems

    Show full item record

    contributor authorYves R. Filion
    contributor authorHeather L. MacLean
    contributor authorBryan W. Karney
    date accessioned2017-05-08T21:21:20Z
    date available2017-05-08T21:21:20Z
    date copyrightSeptember 2004
    date issued2004
    identifier other%28asce%291076-0342%282004%2910%3A3%28119%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48204
    description abstractThe paper presents a life-cycle energy analysis (LCEA) to quantify energy expenditures in the fabrication, use, and end-of-life stages of the pipes of a water distribution system. The methodology incorporates the capabilities of environmental input-output life-cycle analysis to quantify the energy required to fabricate pipes. The EPANET2 hydraulic model is applied in conjunction with a pipe-aging model to calculate the theoretical energy recovery in the use stage. An exponential pipe-break model is applied to quantify the energy required to repair pipe breaks during the use stage of a system. Simple formulations are developed to estimate the energy required to dispose of and recycle pipes once their service period has expired. The LCEA methodology is then applied to the New York City (NYC) water supply tunnels example to quantify energy expenditures in four planning scenarios with 10-, 20-, 50-, and 100-year pipe replacement frequencies. The results of the NYC example highlight the tension between the energy costs incurred in the fabrication and end-of-life stages of a system and those incurred in the use stage. A pipe-replacement period roughly equal to 50 years yielded the lowest overall energy expenditure in the three life stages. A sensitivity analysis was carried out to assess the influence of uncertain system parameters on energy expenditure estimates.
    publisherAmerican Society of Civil Engineers
    titleLife-Cycle Energy Analysis of a Water Distribution System
    typeJournal Paper
    journal volume10
    journal issue3
    journal titleJournal of Infrastructure Systems
    identifier doi10.1061/(ASCE)1076-0342(2004)10:3(119)
    treeJournal of Infrastructure Systems:;2004:;Volume ( 010 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian