    Archive

    Restoration of Cold Storage Factory Building

    Source: Journal of Performance of Constructed Facilities:;2000:;Volume ( 014 ):;issue: 004
    Author:
    N. Subramanian
    DOI: 10.1061/(ASCE)0887-3828(2000)14:4(155)
    Publisher: American Society of Civil Engineers
    Abstract: This paper deals with the renovation of a factory building in Nellore, India. The plan dimensions of this building are 25.7 × 52.5 m. It has concrete columns and the roof is made up of Pratt trusses with hot-rolled steel sections. Because the building is used as a cold storage facility, it is covered with a 130-mm-thick slab, which consists of the following four layers: (1) Roladeck trapezoidal sheeting; (2) one layer of 50-mm-thick concrete; (3) a layer of 40-mm-thick polyurethane foam; and (4) another layer of 40-mm-thick reinforced cement concrete (RCC). A significant amount of deflection was noticed when the scaffolding for the concrete was removed. The reason for this deflection was that most of the members of the trusses were overstressed due to the error of assuming that the truss would support traditional asbestos concrete sheet roofing. The rehabilitation measures included welding of additional steel plates to the members of the trusses. Proper precautions were not taken during welding repairs, which resulted in local buckling of the main members of the trusses. This buckling was mainly due to implementing the welding of the extra plates without providing temporary supports for the trusses, which were already carrying heavy loads. Finally it was decided to introduce intermediate columns that will reduce the force in some truss members. These remedial measures are discussed.
    • Download: (1.041Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Restoration of Cold Storage Factory Building

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/44227
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorN. Subramanian
    date accessioned2017-05-08T21:14:55Z
    date available2017-05-08T21:14:55Z
    date copyrightNovember 2000
    date issued2000
    identifier other%28asce%290887-3828%282000%2914%3A4%28155%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/44227
    description abstractThis paper deals with the renovation of a factory building in Nellore, India. The plan dimensions of this building are 25.7 × 52.5 m. It has concrete columns and the roof is made up of Pratt trusses with hot-rolled steel sections. Because the building is used as a cold storage facility, it is covered with a 130-mm-thick slab, which consists of the following four layers: (1) Roladeck trapezoidal sheeting; (2) one layer of 50-mm-thick concrete; (3) a layer of 40-mm-thick polyurethane foam; and (4) another layer of 40-mm-thick reinforced cement concrete (RCC). A significant amount of deflection was noticed when the scaffolding for the concrete was removed. The reason for this deflection was that most of the members of the trusses were overstressed due to the error of assuming that the truss would support traditional asbestos concrete sheet roofing. The rehabilitation measures included welding of additional steel plates to the members of the trusses. Proper precautions were not taken during welding repairs, which resulted in local buckling of the main members of the trusses. This buckling was mainly due to implementing the welding of the extra plates without providing temporary supports for the trusses, which were already carrying heavy loads. Finally it was decided to introduce intermediate columns that will reduce the force in some truss members. These remedial measures are discussed.
    publisherAmerican Society of Civil Engineers
    titleRestoration of Cold Storage Factory Building
    typeJournal Paper
    journal volume14
    journal issue4
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)0887-3828(2000)14:4(155)
    treeJournal of Performance of Constructed Facilities:;2000:;Volume ( 014 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace