Dynamic Force Effect on Collapse of L'ambiance PlazaSource: Journal of Performance of Constructed Facilities:;1995:;Volume ( 009 ):;issue: 002Author:Rusk Masih
DOI: 10.1061/(ASCE)0887-3828(1995)9:2(129)Publisher: American Society of Civil Engineers
Abstract: All the technical papers written about the April 23, 1987, collapse of L'Ambiance Plaza, Bridgeport, Conn., have treated it by static-analysis methods. It was established that a 12-ton jack was used just prior to the collapse to plumb the building; however, no one attempted to link the dynamic load generated by the force of the jack to the dynamic vulnerability of the lift-slab structures during the construction stage. This paper is an attempt to show that the dynamic vulnerability of the lift slab, combined with the dynamic load such as the one generated by the 12-ton jack, could have caused the dynamic instability of the structure, which led to the collapse.
|
Collections
Show full item record
| contributor author | Rusk Masih | |
| date accessioned | 2017-05-08T21:14:35Z | |
| date available | 2017-05-08T21:14:35Z | |
| date copyright | May 1995 | |
| date issued | 1995 | |
| identifier other | %28asce%290887-3828%281995%299%3A2%28129%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/44050 | |
| description abstract | All the technical papers written about the April 23, 1987, collapse of L'Ambiance Plaza, Bridgeport, Conn., have treated it by static-analysis methods. It was established that a 12-ton jack was used just prior to the collapse to plumb the building; however, no one attempted to link the dynamic load generated by the force of the jack to the dynamic vulnerability of the lift-slab structures during the construction stage. This paper is an attempt to show that the dynamic vulnerability of the lift slab, combined with the dynamic load such as the one generated by the 12-ton jack, could have caused the dynamic instability of the structure, which led to the collapse. | |
| publisher | American Society of Civil Engineers | |
| title | Dynamic Force Effect on Collapse of L'ambiance Plaza | |
| type | Journal Paper | |
| journal volume | 9 | |
| journal issue | 2 | |
| journal title | Journal of Performance of Constructed Facilities | |
| identifier doi | 10.1061/(ASCE)0887-3828(1995)9:2(129) | |
| tree | Journal of Performance of Constructed Facilities:;1995:;Volume ( 009 ):;issue: 002 | |
| contenttype | Fulltext |