    Experimental and Computational Assessment of a Converging–Diverging Funnel Arrangement System for Marine Gas Turbine Applications

    Source: ASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:004::page 717
    Author:
    Mukherjee, Arnab
    ,
    Shrivastav, Harshit
    ,
    Rout, Maheswar
    ,
    Ghosh, Suman
    ,
    Senapati, Jnana Ranjan
    DOI: 10.1115/1.4070960
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. A funnel arrangement system is essential in modern naval ships to cool the hot exhaust gas and suppress its infrared (IR) signature. Laboratory experiments utilizing various funnel designs, specifically converging–diverging funnels, have produced promising results regarding the infrared suppression (IRS) model. The experimental analysis varied the Reynolds number between 4020 and 16,800. At the same time, the temperature ratio was adjusted from 1.1411 to 1.2974, yielding significant insights into the relationship between mass flow dynamics and thermal efficiency in IRS devices. This study proposes a novel type of funnel arrangement system featuring a converging-diverging funnel configuration. The thermo-fluid analysis of the proposed system involves solving transport equations, including continuity, momentum, energy, and turbulence, using the finite volume solver in ANSYS FLUENT. The study aims to determine the effective geometrical parameters, such as the inlet radius, outlet radius, radial overlap, and funnel inclination angle, to optimize the system's performance. The impact of these pertinent parameters on the air entrainment and system exit temperature is elucidated here. The funnel walls are assumed diathermic for the present analysis. The results show that maximum mass entrainment and lowest outlet temperature are achieved at a radial overlap of 0.3 m. A funnel inclination angle of 4 deg shows a maximum mass entrainment.
    • Download: (2.401Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental and Computational Assessment of a Converging–Diverging Funnel Arrangement System for Marine Gas Turbine Applications

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316705
    Collections
    • ASME Journal of Heat and Mass Transfer

    Show full item record

    contributor authorMukherjee, Arnab
    contributor authorShrivastav, Harshit
    contributor authorRout, Maheswar
    contributor authorGhosh, Suman
    contributor authorSenapati, Jnana Ranjan
    date accessioned2026-08-23T08:32:36Z
    date available2026-08-23T08:32:36Z
    date copyright2026/04/01
    date issued2026
    identifier issn2832-8450
    identifier otherht-25-1348.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316705
    description abstractAbstract. A funnel arrangement system is essential in modern naval ships to cool the hot exhaust gas and suppress its infrared (IR) signature. Laboratory experiments utilizing various funnel designs, specifically converging–diverging funnels, have produced promising results regarding the infrared suppression (IRS) model. The experimental analysis varied the Reynolds number between 4020 and 16,800. At the same time, the temperature ratio was adjusted from 1.1411 to 1.2974, yielding significant insights into the relationship between mass flow dynamics and thermal efficiency in IRS devices. This study proposes a novel type of funnel arrangement system featuring a converging-diverging funnel configuration. The thermo-fluid analysis of the proposed system involves solving transport equations, including continuity, momentum, energy, and turbulence, using the finite volume solver in ANSYS FLUENT. The study aims to determine the effective geometrical parameters, such as the inlet radius, outlet radius, radial overlap, and funnel inclination angle, to optimize the system's performance. The impact of these pertinent parameters on the air entrainment and system exit temperature is elucidated here. The funnel walls are assumed diathermic for the present analysis. The results show that maximum mass entrainment and lowest outlet temperature are achieved at a radial overlap of 0.3 m. A funnel inclination angle of 4 deg shows a maximum mass entrainment.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental and Computational Assessment of a Converging–Diverging Funnel Arrangement System for Marine Gas Turbine Applications
    typeJournal Paper
    journal volume148
    journal issue4
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4070960
    journal fristpage717
    journal lastpage727
    page11
    treeASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian