    Surge Inception Point Analysis Using the Greitzer Model for Centrifugal Compressor

    Source: Journal of Turbomachinery:;2026:;volume( 148 ):;issue:004
    Author:
    Basit, Abdul
    ,
    Liskiewicz, Grzegorz
    ,
    Balcerzak, Marek
    DOI: 10.1115/1.4069806
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. For modern centrifugal compressors, the widest operating range is desired. At a low mass flowrate, the operating range is limited by the surge phenomenon described by the Greitzer model. It is widely believed that the surge inception takes place directly at the maximum point of the compressor performance curve. In this study, we are showing the exact surge inception point that can be located behind the curve maximum. The key parameter in the Greitzer model is named B and it should be unique for a given compressor and plenum. According to Greitzer, there is a critical value of B (named Bcr herein) that represents a threshold between stable and unstable system operation. In this study, Bcr is analyzed and determined pointwise along the unstable part of the compressor performance curve. We have found that Bcr is changing with the mass flowrate. This allowed us to find the unique surge inception point for a given model with a known B and compressor performance map. It was also shown that for each compressor performance curve, there exists a limiting Bcr0 value that provides ultimate stability for the system, even at the left-hand side of the performance curve widely considered as unstable. The determined values showed good agreement with selected articles where the surge inception point and the B value of the system were provided. The formula for surge point inception was determined to provide a practical application of the presented theory.
    • Download: (1.000Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Surge Inception Point Analysis Using the Greitzer Model for Centrifugal Compressor

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316612
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorBasit, Abdul
    contributor authorLiskiewicz, Grzegorz
    contributor authorBalcerzak, Marek
    date accessioned2026-08-23T08:29:03Z
    date available2026-08-23T08:29:03Z
    date copyright2026/04/01
    date issued2026
    identifier issn0889-504X
    identifier otherturbo-25-1180.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316612
    description abstractAbstract. For modern centrifugal compressors, the widest operating range is desired. At a low mass flowrate, the operating range is limited by the surge phenomenon described by the Greitzer model. It is widely believed that the surge inception takes place directly at the maximum point of the compressor performance curve. In this study, we are showing the exact surge inception point that can be located behind the curve maximum. The key parameter in the Greitzer model is named B and it should be unique for a given compressor and plenum. According to Greitzer, there is a critical value of B (named Bcr herein) that represents a threshold between stable and unstable system operation. In this study, Bcr is analyzed and determined pointwise along the unstable part of the compressor performance curve. We have found that Bcr is changing with the mass flowrate. This allowed us to find the unique surge inception point for a given model with a known B and compressor performance map. It was also shown that for each compressor performance curve, there exists a limiting Bcr0 value that provides ultimate stability for the system, even at the left-hand side of the performance curve widely considered as unstable. The determined values showed good agreement with selected articles where the surge inception point and the B value of the system were provided. The formula for surge point inception was determined to provide a practical application of the presented theory.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSurge Inception Point Analysis Using the Greitzer Model for Centrifugal Compressor
    typeJournal Paper
    journal volume148
    journal issue4
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.4069806
    treeJournal of Turbomachinery:;2026:;volume( 148 ):;issue:004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian