    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Wind Tunnel Continuous-Scan Acoustic Analysis of Ducted Fan Tones Interacting With a Shielding Wall

    Source: Journal of Turbomachinery:;2026:;volume( 148 ):;issue:004::page 93
    Author:
    Shah, Parthiv N.
    ,
    Hensley, Dan
    ,
    Papamoschou, Dimitri
    ,
    Stephens, David
    DOI: 10.1115/1.4069936
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. High-bypass ratio ducted fans emit tonal and broadband noise in both forward and aft directions. While produced by common mechanisms, the noise radiating in each direction is typically treated as its own directional source. Proper modeling of forward- and aft-emitted fan noise enables more efficient noise suppression strategies. In this article, wind tunnel continuous-scan (CS) acoustic measurements of a fan simulator are analyzed in two configurations: with and without a barrier wall structure. The barrier wall is used to separate the forward-emitted fan noise from the aft-emitted fan noise through shielding. As acoustic shielding is also an important noise reduction strategy for next-generation aircraft, the barrier wall is an effective surrogate to study the effect of propulsion airframe aeroacoustics (PAA), where the wall creates shielding and/or scattering similar to a wing or airframe surface. The goal of this article is to use previously demonstrated high-resolution, CS acoustic analysis methods to (1) decompose isolated fan noise measured in the NASA Glenn Research Center (GRC) 9- by 15-foot (9 × 15) low-speed wind tunnel (LSWT) into respective aft- and forward-emitted source models and (2) predict the fan noise interaction with a barrier wall. Acoustic signals from the scanning microphone are combined with a once-per-revolution tachometer signal to separate each shaft harmonic tone's amplitude and phase in the time domain. The complex pressure envelope obtained from this decomposition is next fit to an axially distributed ring source model by solving an inverse problem. The source model is verified against the isolated tunnel measurement data and then again projected with a line-of-sight barrier wall shielding effect. The barrier wall measurements provide a comparison dataset for the analytical shielding prediction developed from the isolated dataset. Results suggest that the source model localizes the fan sources well enough to perform analytical source separation, offering the potential to eliminate the barrier wall from testing, which would provide a substantial time or cost savings. The findings also suggest that combining high-resolution acoustic measurements with analytical methods could realize an integrated test and analysis paradigm for efficient PAA design.
    • Download: (1.858Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Wind Tunnel Continuous-Scan Acoustic Analysis of Ducted Fan Tones Interacting With a Shielding Wall

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316571
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorShah, Parthiv N.
    contributor authorHensley, Dan
    contributor authorPapamoschou, Dimitri
    contributor authorStephens, David
    date accessioned2026-08-23T08:27:07Z
    date available2026-08-23T08:27:07Z
    date copyright2026/04/01
    date issued2026
    identifier issn0889-504X
    identifier otherturbo-25-1143.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316571
    description abstractAbstract. High-bypass ratio ducted fans emit tonal and broadband noise in both forward and aft directions. While produced by common mechanisms, the noise radiating in each direction is typically treated as its own directional source. Proper modeling of forward- and aft-emitted fan noise enables more efficient noise suppression strategies. In this article, wind tunnel continuous-scan (CS) acoustic measurements of a fan simulator are analyzed in two configurations: with and without a barrier wall structure. The barrier wall is used to separate the forward-emitted fan noise from the aft-emitted fan noise through shielding. As acoustic shielding is also an important noise reduction strategy for next-generation aircraft, the barrier wall is an effective surrogate to study the effect of propulsion airframe aeroacoustics (PAA), where the wall creates shielding and/or scattering similar to a wing or airframe surface. The goal of this article is to use previously demonstrated high-resolution, CS acoustic analysis methods to (1) decompose isolated fan noise measured in the NASA Glenn Research Center (GRC) 9- by 15-foot (9 × 15) low-speed wind tunnel (LSWT) into respective aft- and forward-emitted source models and (2) predict the fan noise interaction with a barrier wall. Acoustic signals from the scanning microphone are combined with a once-per-revolution tachometer signal to separate each shaft harmonic tone's amplitude and phase in the time domain. The complex pressure envelope obtained from this decomposition is next fit to an axially distributed ring source model by solving an inverse problem. The source model is verified against the isolated tunnel measurement data and then again projected with a line-of-sight barrier wall shielding effect. The barrier wall measurements provide a comparison dataset for the analytical shielding prediction developed from the isolated dataset. Results suggest that the source model localizes the fan sources well enough to perform analytical source separation, offering the potential to eliminate the barrier wall from testing, which would provide a substantial time or cost savings. The findings also suggest that combining high-resolution acoustic measurements with analytical methods could realize an integrated test and analysis paradigm for efficient PAA design.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleWind Tunnel Continuous-Scan Acoustic Analysis of Ducted Fan Tones Interacting With a Shielding Wall
    typeJournal Paper
    journal volume148
    journal issue4
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.4069936
    journal fristpage93
    journal lastpage102
    page10
    treeJournal of Turbomachinery:;2026:;volume( 148 ):;issue:004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian