    Numerical Simulation and Optimization of Thin-Film Evaporation in Variable Micropillar Wicks

    Source: ASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:003::page 122
    Author:
    Zhou, Yimin
    ,
    Adera, Solomon
    DOI: 10.1115/1.4070734
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Thin-film evaporation in micropillar wicking structures is a promising passive cooling strategy for high heat flux electronics. This study numerically investigates thin-film evaporation in well-defined silicon micropillar wicks, where water is transported passively via capillary wicking from the reservoir to the evaporator. A coupled force balance and conservation law framework is employed to determine the meniscus shape, capillary pressure, fluid velocity in the micropillar wicks, and associated heat transfer characteristics. The dry-out heat flux, defined as the maximum heat flux the evaporator can dissipate when the smallest contact angle equals the receding contact angle, is evaluated for different wick designs. For uniform wicks with fixed micropillar geometry, the maximum dry-out heat flux is ≈84 W/cm2. To enhance thermo-fluidic performance, variable wicks are designed with sparse micropillars near the water reservoir and dense micropillars near the evaporator center. By dividing the wick into multiple sections with optimized diameters, the dry-out heat flux reaches ≈147 W/cm2, a 75% improvement over uniform wicks. Further optimization of the variable wicks using a genetic algorithm (GA) increases the dry-out heat flux to ≈165 W/cm2, a 96% enhancement compared to uniform wicks. Unlike uniform wicks, where dry-out starts at the evaporator center, optimized variable wicks experience dry-out at an intermediate location due to increased capillary pressure near the center. These findings provide useful insights into the design and optimization of wicking structures for thin-film evaporation in advanced passive cooling of electronic devices.
    • Download: (1.905Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Numerical Simulation and Optimization of Thin-Film Evaporation in Variable Micropillar Wicks

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316450
    Collections
    • ASME Journal of Heat and Mass Transfer

    Show full item record

    contributor authorZhou, Yimin
    contributor authorAdera, Solomon
    date accessioned2026-08-23T08:22:01Z
    date available2026-08-23T08:22:01Z
    date copyright2026/03/01
    date issued2026
    identifier issn2832-8450
    identifier otherht-25-1120.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316450
    description abstractAbstract. Thin-film evaporation in micropillar wicking structures is a promising passive cooling strategy for high heat flux electronics. This study numerically investigates thin-film evaporation in well-defined silicon micropillar wicks, where water is transported passively via capillary wicking from the reservoir to the evaporator. A coupled force balance and conservation law framework is employed to determine the meniscus shape, capillary pressure, fluid velocity in the micropillar wicks, and associated heat transfer characteristics. The dry-out heat flux, defined as the maximum heat flux the evaporator can dissipate when the smallest contact angle equals the receding contact angle, is evaluated for different wick designs. For uniform wicks with fixed micropillar geometry, the maximum dry-out heat flux is ≈84 W/cm2. To enhance thermo-fluidic performance, variable wicks are designed with sparse micropillars near the water reservoir and dense micropillars near the evaporator center. By dividing the wick into multiple sections with optimized diameters, the dry-out heat flux reaches ≈147 W/cm2, a 75% improvement over uniform wicks. Further optimization of the variable wicks using a genetic algorithm (GA) increases the dry-out heat flux to ≈165 W/cm2, a 96% enhancement compared to uniform wicks. Unlike uniform wicks, where dry-out starts at the evaporator center, optimized variable wicks experience dry-out at an intermediate location due to increased capillary pressure near the center. These findings provide useful insights into the design and optimization of wicking structures for thin-film evaporation in advanced passive cooling of electronic devices.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNumerical Simulation and Optimization of Thin-Film Evaporation in Variable Micropillar Wicks
    typeJournal Paper
    journal volume148
    journal issue3
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4070734
    journal fristpage122
    journal lastpage141
    page20
    treeASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian