    Dependence of Localized Necking Behavior on the Specimen Shapes in Tensile Testing of Ultra-Thin Copper Alloy Sheet

    Source: Journal of Engineering Materials and Technology:;2026:;volume( 148 ):;issue:003::page 682
    Author:
    Ueshima, Nobufumi
    ,
    Oya, Tetsuo
    ,
    Oikawa, Katsunari
    ,
    Ito, Koichi
    ,
    Hyodo, Hiroshi
    ,
    Yorifuji, Hiroshi
    DOI: 10.1115/1.4071221
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. The effect of specimen shape on the fracture angle in tensile testing of copper alloy sheets was investigated. Specimens with a width-to-thickness ratio of more than 30 were investigated, and it was found that relatively thick and narrow copper alloy sheets exhibited a fracture angle oblique to the loading direction. In contrast, the fracture angle was perpendicular to the loading direction in the thinner and wider specimens. To understand the mechanism of the change in fracture direction, digital image correlation (DIC) analysis was performed. The DIC analysis showed that the oblique localizations of the strain rate appeared in two directions in any thickness and width after diffuse necking. In thick specimens, one of the localizations was selected by the oblique fracture. In contrast, two localizations remained until the perpendicular fracture in thin and wide specimens. The analysis of the ratio of local strain rate revealed that the length strain over width strain was basically unchanged until fracture. However, in a few cases, the length strain over width strain drastically changed just before the fracture. These results suggest that the remaining two localized strain rates and the change in the strain state lead to the perpendicular fracture in thin and wide specimen. Regarding the edge of the specimen, the fracture angle tends to be oblique. This is presumably due to the less constrained condition of the edge, which is the possible reason for the oblique fracture of the narrow specimen.
    • Download: (1.406Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Dependence of Localized Necking Behavior on the Specimen Shapes in Tensile Testing of Ultra-Thin Copper Alloy Sheet

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316337
    Collections
    • Journal of Engineering Materials and Technology

    Show full item record

    contributor authorUeshima, Nobufumi
    contributor authorOya, Tetsuo
    contributor authorOikawa, Katsunari
    contributor authorIto, Koichi
    contributor authorHyodo, Hiroshi
    contributor authorYorifuji, Hiroshi
    date accessioned2026-08-23T08:17:30Z
    date available2026-08-23T08:17:30Z
    date copyright2026/07/01
    date issued2026
    identifier issn0094-4289
    identifier othermats-25-1147.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316337
    description abstractAbstract. The effect of specimen shape on the fracture angle in tensile testing of copper alloy sheets was investigated. Specimens with a width-to-thickness ratio of more than 30 were investigated, and it was found that relatively thick and narrow copper alloy sheets exhibited a fracture angle oblique to the loading direction. In contrast, the fracture angle was perpendicular to the loading direction in the thinner and wider specimens. To understand the mechanism of the change in fracture direction, digital image correlation (DIC) analysis was performed. The DIC analysis showed that the oblique localizations of the strain rate appeared in two directions in any thickness and width after diffuse necking. In thick specimens, one of the localizations was selected by the oblique fracture. In contrast, two localizations remained until the perpendicular fracture in thin and wide specimens. The analysis of the ratio of local strain rate revealed that the length strain over width strain was basically unchanged until fracture. However, in a few cases, the length strain over width strain drastically changed just before the fracture. These results suggest that the remaining two localized strain rates and the change in the strain state lead to the perpendicular fracture in thin and wide specimen. Regarding the edge of the specimen, the fracture angle tends to be oblique. This is presumably due to the less constrained condition of the edge, which is the possible reason for the oblique fracture of the narrow specimen.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDependence of Localized Necking Behavior on the Specimen Shapes in Tensile Testing of Ultra-Thin Copper Alloy Sheet
    typeJournal Paper
    journal volume148
    journal issue3
    journal titleJournal of Engineering Materials and Technology
    identifier doi10.1115/1.4071221
    journal fristpage682
    journal lastpage714
    page33
    treeJournal of Engineering Materials and Technology:;2026:;volume( 148 ):;issue:003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian