    Archive

    Prevalent Low Interfacial Fatigue Threshold in Pressure-Sensitive Adhesives

    Source: Journal of Applied Mechanics:;2026:;volume( 093 ):;issue:003::page 434
    Author:
    Wan, Yichen
    ,
    Bai, Ruobing
    DOI: 10.1115/1.4070822
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. The expanding applications of pressure-sensitive adhesives (PSAs) in fields like bioelectronics, healthcare, and flexible displays call for an urgent study on their fatigue behaviors, i.e., damage and fracture under prolonged dynamic loads. However, such studies have been sparse in the field. Here, we show a prevalent low interfacial fatigue threshold in various PSAs through experimental cyclic peeling tests. We characterize interfacial fatigue fracture in PSAs, including the 3M Scotch VHB 4905 tape, the 3M Scotch heavy-duty shipping packaging tape, and two homemade PSAs. The two homemade PSAs consist of different poly(butyl acrylate) elastomeric bulks (low-hysteresis and high-hysteresis) dip-coated with identical viscoelastic poly(butyl acrylate-co-isobornyl acrylate) sticky surface layers. The measured interfacial fatigue thresholds are 3.7 J/m2, 10.8 J/m2, 9.8 J/m2, and 8.1 J/m2 for VHB, packaging tape, low-hysteresis PSA, and high-hysteresis PSA, respectively, all much lower than their bulk adhesion toughnesses at finite crack speeds. The interfacial fatigue threshold agrees qualitatively well with a modified Lake-Thomas model despite an underestimation of the model. However, the measured slow crack threshold in monotonic peeling is larger than the fatigue threshold and shows clear dependence on the bulk dissipation. We discuss possible mechanisms for these discrepancies and potential toughening strategies for PSAs. The new experimental data confirm the prevalence of low interfacial fatigue threshold in PSAs, and further suggest that the threshold is nearly independent of their bulk dissipation.
    • Download: (1.405Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Prevalent Low Interfacial Fatigue Threshold in Pressure-Sensitive Adhesives

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316048
    Collections
    • Journal of Applied Mechanics

    Show full item record

    contributor authorWan, Yichen
    contributor authorBai, Ruobing
    date accessioned2026-08-23T08:04:43Z
    date available2026-08-23T08:04:43Z
    date copyright2026/03/01
    date issued2026
    identifier issn0021-8936
    identifier otherjam-25-1439.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316048
    description abstractAbstract. The expanding applications of pressure-sensitive adhesives (PSAs) in fields like bioelectronics, healthcare, and flexible displays call for an urgent study on their fatigue behaviors, i.e., damage and fracture under prolonged dynamic loads. However, such studies have been sparse in the field. Here, we show a prevalent low interfacial fatigue threshold in various PSAs through experimental cyclic peeling tests. We characterize interfacial fatigue fracture in PSAs, including the 3M Scotch VHB 4905 tape, the 3M Scotch heavy-duty shipping packaging tape, and two homemade PSAs. The two homemade PSAs consist of different poly(butyl acrylate) elastomeric bulks (low-hysteresis and high-hysteresis) dip-coated with identical viscoelastic poly(butyl acrylate-co-isobornyl acrylate) sticky surface layers. The measured interfacial fatigue thresholds are 3.7 J/m2, 10.8 J/m2, 9.8 J/m2, and 8.1 J/m2 for VHB, packaging tape, low-hysteresis PSA, and high-hysteresis PSA, respectively, all much lower than their bulk adhesion toughnesses at finite crack speeds. The interfacial fatigue threshold agrees qualitatively well with a modified Lake-Thomas model despite an underestimation of the model. However, the measured slow crack threshold in monotonic peeling is larger than the fatigue threshold and shows clear dependence on the bulk dissipation. We discuss possible mechanisms for these discrepancies and potential toughening strategies for PSAs. The new experimental data confirm the prevalence of low interfacial fatigue threshold in PSAs, and further suggest that the threshold is nearly independent of their bulk dissipation.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePrevalent Low Interfacial Fatigue Threshold in Pressure-Sensitive Adhesives
    typeJournal Paper
    journal volume93
    journal issue3
    journal titleJournal of Applied Mechanics
    identifier doi10.1115/1.4070822
    journal fristpage434
    journal lastpage439
    page6
    treeJournal of Applied Mechanics:;2026:;volume( 093 ):;issue:003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian