Impact of Heating Electrification and Building Retrofit on the Indoor Thermal Environment and Electricity DemandSource: ASME Journal of Engineering for Sustainable Buildings and Cities:;2026:;volume( 007 ):;issue:001::page 75DOI: 10.1115/1.4070641Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Abstract. Retrofitting building stock through heating electrification and energy efficiency improvements is essential for achieving carbon neutrality. Understanding the effects of electrification and efficiency retrofits on building-resident satisfaction and adaptive behaviors is important, as these directly impact retrofitting success, adoption rates, energy consumption, and performance. There is a gap in understanding the combined effects of heating electrification and building efficiency retrofits. Using data collected over 2.5 years, we performed integrated qualitative and quantitative analyses to evaluate the combined effects of heat pump electrification and a roof insulation retrofitting in a 10-unit New York City apartment building. Building-resident satisfaction with each strategy was assessed, and impacts on occupant thermal comfort, energy behavior, indoor thermal environment, and energy consumption were analyzed. Despite perceived challenges and resident skepticism, air source heat pumps (ASHPs) provided adequate indoor thermal comfort. ASHPs were preferred over steam boiler heating for controllability, noise reduction, and improved thermal comfort. Unintended benefits included improved aesthetics, reduced real estate needs, and decreased burn potential. With heat pumps, some residents adopted energy-conservative behaviors while others adopted “comfort-taking” behaviors, prioritizing comfort over conservation. The roof insulation retrofit further improved resident thermal comfort and decreased total building heating energy requirements by 25.3–34.2% and heating peak power requirements by 10.7%. The retrofit also improved ASHP efficiency in previously uninsulated spaces, effectively mitigating heat pump undersizing effects. Combined energy retrofitting strategies could play a key role in ensuring thermal comfort and building energy efficiency toward carbon neutrality.
|
Show full item record
| contributor author | Rodriguez, Alfredo A. | |
| contributor author | Amadeh, Ali | |
| contributor author | Lee, Zachary E. | |
| contributor author | Humphreys, Lee | |
| contributor author | Zhang, K. Max | |
| date accessioned | 2026-08-23T08:00:14Z | |
| date available | 2026-08-23T08:00:14Z | |
| date copyright | 2026/02/01 | |
| date issued | 2026 | |
| identifier issn | 2642-6641 | |
| identifier other | jesbc-25-1050.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4315934 | |
| description abstract | Abstract. Retrofitting building stock through heating electrification and energy efficiency improvements is essential for achieving carbon neutrality. Understanding the effects of electrification and efficiency retrofits on building-resident satisfaction and adaptive behaviors is important, as these directly impact retrofitting success, adoption rates, energy consumption, and performance. There is a gap in understanding the combined effects of heating electrification and building efficiency retrofits. Using data collected over 2.5 years, we performed integrated qualitative and quantitative analyses to evaluate the combined effects of heat pump electrification and a roof insulation retrofitting in a 10-unit New York City apartment building. Building-resident satisfaction with each strategy was assessed, and impacts on occupant thermal comfort, energy behavior, indoor thermal environment, and energy consumption were analyzed. Despite perceived challenges and resident skepticism, air source heat pumps (ASHPs) provided adequate indoor thermal comfort. ASHPs were preferred over steam boiler heating for controllability, noise reduction, and improved thermal comfort. Unintended benefits included improved aesthetics, reduced real estate needs, and decreased burn potential. With heat pumps, some residents adopted energy-conservative behaviors while others adopted “comfort-taking” behaviors, prioritizing comfort over conservation. The roof insulation retrofit further improved resident thermal comfort and decreased total building heating energy requirements by 25.3–34.2% and heating peak power requirements by 10.7%. The retrofit also improved ASHP efficiency in previously uninsulated spaces, effectively mitigating heat pump undersizing effects. Combined energy retrofitting strategies could play a key role in ensuring thermal comfort and building energy efficiency toward carbon neutrality. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Impact of Heating Electrification and Building Retrofit on the Indoor Thermal Environment and Electricity Demand | |
| type | Journal Paper | |
| journal volume | 7 | |
| journal issue | 1 | |
| journal title | ASME Journal of Engineering for Sustainable Buildings and Cities | |
| identifier doi | 10.1115/1.4070641 | |
| journal fristpage | 75 | |
| journal lastpage | 83 | |
| page | 9 | |
| tree | ASME Journal of Engineering for Sustainable Buildings and Cities:;2026:;volume( 007 ):;issue:001 | |
| contenttype | Fulltext |