    An Innovative Technique for Approximate Analytical Solutions of Blood Flow in a Stenotic Artery

    Source: Journal of Computational and Nonlinear Dynamics:;2026:;volume( 021 ):;issue:002
    Author:
    Al-Salih, Ammar
    ,
    Jaber Al-Saif, Abdul-Sattar
    DOI: 10.1115/1.4070284
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. The objective of this study is to propose an innovative method for obtaining an approximate analytical solution to a problem describing the flow of a hybrid nanofluid, composed of aluminum oxide (Al2O3) and copper (Cu) nanoparticles suspended in blood, within a stenosed artery. This approach combines Shehu transform (ST) with reduced differential transform method, resulting in a novel hybrid technique referred to as Shehu transform reduced differential transform method (SRDTM). The governing flow equations are first reduced to ordinary differential equations using a similarity transformation and subsequently solved with the developed method. The reliability of SRDTM is validated through comparative tables, which show excellent agreement between the obtained results and those reported in previous studies. Furthermore, graphical illustrations are used to investigate the effects of various physical parameters, including volume fraction, flow rate parameter, Prandtl number, Nusselt number, and skin friction coefficient, on velocity and temperature profiles of blood flow in stenosed arteries. Additionally, error tables and both theoretical and computational convergence analyses further confirm the efficiency, accuracy, and effectiveness of the proposed method compared to reduced differential transform method.
    • Download: (1.807Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      An Innovative Technique for Approximate Analytical Solutions of Blood Flow in a Stenotic Artery

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4315623
    Collections
    • Journal of Computational and Nonlinear Dynamics

    Show full item record

    contributor authorAl-Salih, Ammar
    contributor authorJaber Al-Saif, Abdul-Sattar
    date accessioned2026-08-23T07:48:02Z
    date available2026-08-23T07:48:02Z
    date copyright2026/02/01
    date issued2026
    identifier issn1555-1415
    identifier othercnd-25-1118.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315623
    description abstractAbstract. The objective of this study is to propose an innovative method for obtaining an approximate analytical solution to a problem describing the flow of a hybrid nanofluid, composed of aluminum oxide (Al2O3) and copper (Cu) nanoparticles suspended in blood, within a stenosed artery. This approach combines Shehu transform (ST) with reduced differential transform method, resulting in a novel hybrid technique referred to as Shehu transform reduced differential transform method (SRDTM). The governing flow equations are first reduced to ordinary differential equations using a similarity transformation and subsequently solved with the developed method. The reliability of SRDTM is validated through comparative tables, which show excellent agreement between the obtained results and those reported in previous studies. Furthermore, graphical illustrations are used to investigate the effects of various physical parameters, including volume fraction, flow rate parameter, Prandtl number, Nusselt number, and skin friction coefficient, on velocity and temperature profiles of blood flow in stenosed arteries. Additionally, error tables and both theoretical and computational convergence analyses further confirm the efficiency, accuracy, and effectiveness of the proposed method compared to reduced differential transform method.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Innovative Technique for Approximate Analytical Solutions of Blood Flow in a Stenotic Artery
    typeJournal Paper
    journal volume21
    journal issue2
    journal titleJournal of Computational and Nonlinear Dynamics
    identifier doi10.1115/1.4070284
    treeJournal of Computational and Nonlinear Dynamics:;2026:;volume( 021 ):;issue:002
    contenttypeFulltext