    Archive

    Autofeelment: Design and Development of an Automated Monofilament Testing Device for Peripheral Diabetic Neuropathy

    Source: Journal of Medical Devices:;2026:;volume( 020 ):;issue:005
    Author:
    Sundar, Ilesh
    ,
    Veliah, Geetha
    DOI: 10.1115/1.4071690
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Peripheral diabetic neuropathy is a common complication of diabetes mellitus and is associated with progressive loss of protective sensation in the feet, increasing the risk of ulcers and lower-limb complications. The Semmes–Weinstein monofilament test is widely used to assess protective sensation; however, variability in manual administration may affect consistency in test delivery across settings. This study presents the design, development, and mechanical validation of Autofeelment, an automated device intended to standardize the application of the monofilament test through controlled actuation and sequencing. The device consists of a mechanical platform with four linear actuators, a microcontroller-based control system, and a smartphone interface to enable automated testing at predefined plantar locations. Mechanical validation was conducted using healthy volunteers to assess timing consistency, actuator performance, and usability. Ten participants each completed three consecutive testing trials, resulting in 30 validation trials and 120 actuator extensions. The device demonstrated a mean testing time of 10.409±0.019 s, corresponding to a coefficient of variation of 0.18%. Successful monofilament buckling was achieved in 118 of 120 actuator extensions (98.3%). Participants reported high levels of comfort (mean 4.6/5) and ease of use (mean 4.8/5), with no adverse events observed. These findings demonstrate the mechanical reliability, temporal consistency, and usability of the Autofeelment device as a prototype system. This study does not evaluate diagnostic accuracy or clinical effectiveness. Further work is required to validate automated monofilament testing in diabetic populations and to compare performance with standard manual testing methods.
    • Download: (881.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Autofeelment: Design and Development of an Automated Monofilament Testing Device for Peripheral Diabetic Neuropathy

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4315605
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorSundar, Ilesh
    contributor authorVeliah, Geetha
    date accessioned2026-08-23T07:47:16Z
    date available2026-08-23T07:47:16Z
    date copyright2026/10/01
    date issued2026
    identifier issn1932-6181
    identifier othermed-25-1220.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315605
    description abstractAbstract. Peripheral diabetic neuropathy is a common complication of diabetes mellitus and is associated with progressive loss of protective sensation in the feet, increasing the risk of ulcers and lower-limb complications. The Semmes–Weinstein monofilament test is widely used to assess protective sensation; however, variability in manual administration may affect consistency in test delivery across settings. This study presents the design, development, and mechanical validation of Autofeelment, an automated device intended to standardize the application of the monofilament test through controlled actuation and sequencing. The device consists of a mechanical platform with four linear actuators, a microcontroller-based control system, and a smartphone interface to enable automated testing at predefined plantar locations. Mechanical validation was conducted using healthy volunteers to assess timing consistency, actuator performance, and usability. Ten participants each completed three consecutive testing trials, resulting in 30 validation trials and 120 actuator extensions. The device demonstrated a mean testing time of 10.409±0.019 s, corresponding to a coefficient of variation of 0.18%. Successful monofilament buckling was achieved in 118 of 120 actuator extensions (98.3%). Participants reported high levels of comfort (mean 4.6/5) and ease of use (mean 4.8/5), with no adverse events observed. These findings demonstrate the mechanical reliability, temporal consistency, and usability of the Autofeelment device as a prototype system. This study does not evaluate diagnostic accuracy or clinical effectiveness. Further work is required to validate automated monofilament testing in diabetic populations and to compare performance with standard manual testing methods.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAutofeelment: Design and Development of an Automated Monofilament Testing Device for Peripheral Diabetic Neuropathy
    typeJournal Paper
    journal volume20
    journal issue5
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4071690
    treeJournal of Medical Devices:;2026:;volume( 020 ):;issue:005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian