    Intraoperative Dual-Cantilever Probe for Rapid Measurement of Cancellous Bone Compressive Strength Within the Vertebral Body

    Source: Journal of Medical Devices:;2026:;volume( 020 ):;issue:002
    Author:
    Kresse, Owen
    ,
    Khong, Evelyn
    ,
    Loohuis, Gerhardus O.
    ,
    Elayne Shelby, R.
    ,
    Boakye, Maxwell
    ,
    Voor, Michael J.
    ,
    Williams, Stuart J.
    DOI: 10.1115/1.4070666
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Dual X-ray absorptiometry (DEXA) scans are the current standard in assessing bone mineral density (BMD) and are used to identify patients who may need screw augmentation during spinal fusion. DEXA scans are not always available and tend to overestimate BMD. This paper describes the development of a dual-cantilever mechanical probe and tested in polyurethane foam blocks with varying compressive strengths. The probe was modeled after a 5.5 mm tap and foam block holes were prepared replicating intra-operative conditions. Calibration curves were acquired for each probe using six foam blocks (1.5–12.9 MPa). Verification tests were performed in a different set of four foam blocks (2.05–9.65 MPa). Four probes were machined and tested for repeatability. Three users separately acquired measurements of foam blocks to test for reliability. The root-mean-square error of all four probes measuring the 2.05 MPa, 3.65 MPa, 5.80 MPa, and 9.65 MPa samples were 0.89 MPa, 0.32 MPa, 1.41 MPa, and 1.71 MPa, respectively. There was not a significant difference between different probes or different users. The dual-cantilever probe provided measurements within the clinically relevant range of compressive strengths for vertebral trabecular bone. A targeted and reliable bone strength measurement technique could reduce the occurrence and revision surgeries and improve patient outcomes.
    • Download: (1.348Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Intraoperative Dual-Cantilever Probe for Rapid Measurement of Cancellous Bone Compressive Strength Within the Vertebral Body

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4315573
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorKresse, Owen
    contributor authorKhong, Evelyn
    contributor authorLoohuis, Gerhardus O.
    contributor authorElayne Shelby, R.
    contributor authorBoakye, Maxwell
    contributor authorVoor, Michael J.
    contributor authorWilliams, Stuart J.
    date accessioned2026-08-23T07:46:04Z
    date available2026-08-23T07:46:04Z
    date copyright2026/04/01
    date issued2026
    identifier issn1932-6181
    identifier othermed-25-1069.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315573
    description abstractAbstract. Dual X-ray absorptiometry (DEXA) scans are the current standard in assessing bone mineral density (BMD) and are used to identify patients who may need screw augmentation during spinal fusion. DEXA scans are not always available and tend to overestimate BMD. This paper describes the development of a dual-cantilever mechanical probe and tested in polyurethane foam blocks with varying compressive strengths. The probe was modeled after a 5.5 mm tap and foam block holes were prepared replicating intra-operative conditions. Calibration curves were acquired for each probe using six foam blocks (1.5–12.9 MPa). Verification tests were performed in a different set of four foam blocks (2.05–9.65 MPa). Four probes were machined and tested for repeatability. Three users separately acquired measurements of foam blocks to test for reliability. The root-mean-square error of all four probes measuring the 2.05 MPa, 3.65 MPa, 5.80 MPa, and 9.65 MPa samples were 0.89 MPa, 0.32 MPa, 1.41 MPa, and 1.71 MPa, respectively. There was not a significant difference between different probes or different users. The dual-cantilever probe provided measurements within the clinically relevant range of compressive strengths for vertebral trabecular bone. A targeted and reliable bone strength measurement technique could reduce the occurrence and revision surgeries and improve patient outcomes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIntraoperative Dual-Cantilever Probe for Rapid Measurement of Cancellous Bone Compressive Strength Within the Vertebral Body
    typeJournal Paper
    journal volume20
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4070666
    treeJournal of Medical Devices:;2026:;volume( 020 ):;issue:002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian