    Archive

    A Finite Element Framework to Study Trauma Risk During Daily Physical Activities on Patients With an Implanted Port-a-Cath

    Source: Journal of Medical Devices:;2026:;volume( 020 ):;issue:001::page 783
    Author:
    Lissoni, Vittorio
    ,
    Luraghi, Giulia
    ,
    Campagna, Federica
    ,
    Massimino, Maura
    ,
    Morosi, Carlo
    ,
    Spreafico, Filippo
    ,
    Matas, Jose Felix Rodriguez
    DOI: 10.1115/1.4070258
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. A Port-a-cath is an implantable device placed under the skin to draw blood or deliver treatments such as intravenous fluids, medications, or transfusions. Patients often worry about accidentally hitting the device or nearby tissues, as it slightly protrudes from the skin. This concern can limit participation in daily activities, including sports, affecting quality of life. In this study, we propose a framework to investigate the risk of accidental tissue trauma by simulating a ball impact in the area surrounding an implanted Port-a-cath using finite element analysis. The simulation revealed increased stress in tissues surrounding the device (approximately five times higher in both the skin and the muscle when the device is implanted), suggesting a potential risk for muscle injury upon impact. These findings highlight the need for awareness regarding external forces acting on the Port-a-cath region during physical activity. To our knowledge, this is the first study using biomechanical modeling to explore trauma risk associated with Port-a-cath impacts. This study represents the first attempt to elucidate this risk in the literature. Overall, this study contributes to improving patient safety and quality of life by providing a quantitative understanding of the mechanical risks associated with implanted Port-a-caths.
    • Download: (1.228Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Finite Element Framework to Study Trauma Risk During Daily Physical Activities on Patients With an Implanted Port-a-Cath

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4315556
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorLissoni, Vittorio
    contributor authorLuraghi, Giulia
    contributor authorCampagna, Federica
    contributor authorMassimino, Maura
    contributor authorMorosi, Carlo
    contributor authorSpreafico, Filippo
    contributor authorMatas, Jose Felix Rodriguez
    date accessioned2026-08-23T07:45:26Z
    date available2026-08-23T07:45:26Z
    date copyright2026/02/01
    date issued2026
    identifier issn1932-6181
    identifier othermed-25-1122.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315556
    description abstractAbstract. A Port-a-cath is an implantable device placed under the skin to draw blood or deliver treatments such as intravenous fluids, medications, or transfusions. Patients often worry about accidentally hitting the device or nearby tissues, as it slightly protrudes from the skin. This concern can limit participation in daily activities, including sports, affecting quality of life. In this study, we propose a framework to investigate the risk of accidental tissue trauma by simulating a ball impact in the area surrounding an implanted Port-a-cath using finite element analysis. The simulation revealed increased stress in tissues surrounding the device (approximately five times higher in both the skin and the muscle when the device is implanted), suggesting a potential risk for muscle injury upon impact. These findings highlight the need for awareness regarding external forces acting on the Port-a-cath region during physical activity. To our knowledge, this is the first study using biomechanical modeling to explore trauma risk associated with Port-a-cath impacts. This study represents the first attempt to elucidate this risk in the literature. Overall, this study contributes to improving patient safety and quality of life by providing a quantitative understanding of the mechanical risks associated with implanted Port-a-caths.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Finite Element Framework to Study Trauma Risk During Daily Physical Activities on Patients With an Implanted Port-a-Cath
    typeJournal Paper
    journal volume20
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4070258
    journal fristpage783
    journal lastpage791
    page9
    treeJournal of Medical Devices:;2026:;volume( 020 ):;issue:001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian