    Effect of Diffuser Inlet Angles on the Power and Torque Coefficients of a Hydrokinetic Turbine

    Source: Journal of Offshore Mechanics and Arctic Engineering:;2026:;volume( 148 ):;issue:001
    Author:
    Ng, Cheng Yee
    ,
    Maldar, Nauman Riyaz
    ,
    Ong, Muk Chen
    DOI: 10.1115/1.4069635
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Ocean current energy is a promising ocean renewable energy source. The Savonius hydrokinetic turbine (HKT) is known for its simplicity and adaptability in low-velocity ocean currents, but its efficiency is generally lower than that of other turbine types. This study investigates the optimization of diffuser inlet opening angles and their effect on the power output of a Savonius HKT using flow-3d simulations with the unsteady Reynolds-averaged Navier–Stokes equations and the RNG k-ε turbulence model. Five inlet angles (θi = 15 deg, 20 deg, 25 deg, 30 deg, and 35 deg) are tested to evaluate their impact on flow velocity, power coefficient (Cp), and torque coefficient (Ct). Refinement level 7 (RL7) is used for all analyses, ensuring consistent mesh resolution. Six domain sizes are tested to assess boundary effects, confirming that D4 balances accuracy and computational efficiency. The time-step analysis identifies TS5 as the optimal time-step. Results show that the 20 deg inlet angle achieves the highest Cp of 0.447 and Ct of 0.628 compared other angles. It also enhances Cp by 38% and Ct by 28% compared to a turbine without a diffuser. This validates the effectiveness of the 20 deg configuration. This study demonstrates that optimizing the diffuser inlet opening angle, particularly θi = 20 deg, can enhance the HKT efficiency.
    • Download: (872.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effect of Diffuser Inlet Angles on the Power and Torque Coefficients of a Hydrokinetic Turbine

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4315476
    Collections
    • Journal of Offshore Mechanics and Arctic Engineering

    Show full item record

    contributor authorNg, Cheng Yee
    contributor authorMaldar, Nauman Riyaz
    contributor authorOng, Muk Chen
    date accessioned2026-08-23T07:42:20Z
    date available2026-08-23T07:42:20Z
    date copyright2026/02/01
    date issued2026
    identifier issn0892-7219
    identifier otheromae-24-1213.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315476
    description abstractAbstract. Ocean current energy is a promising ocean renewable energy source. The Savonius hydrokinetic turbine (HKT) is known for its simplicity and adaptability in low-velocity ocean currents, but its efficiency is generally lower than that of other turbine types. This study investigates the optimization of diffuser inlet opening angles and their effect on the power output of a Savonius HKT using flow-3d simulations with the unsteady Reynolds-averaged Navier–Stokes equations and the RNG k-ε turbulence model. Five inlet angles (θi = 15 deg, 20 deg, 25 deg, 30 deg, and 35 deg) are tested to evaluate their impact on flow velocity, power coefficient (Cp), and torque coefficient (Ct). Refinement level 7 (RL7) is used for all analyses, ensuring consistent mesh resolution. Six domain sizes are tested to assess boundary effects, confirming that D4 balances accuracy and computational efficiency. The time-step analysis identifies TS5 as the optimal time-step. Results show that the 20 deg inlet angle achieves the highest Cp of 0.447 and Ct of 0.628 compared other angles. It also enhances Cp by 38% and Ct by 28% compared to a turbine without a diffuser. This validates the effectiveness of the 20 deg configuration. This study demonstrates that optimizing the diffuser inlet opening angle, particularly θi = 20 deg, can enhance the HKT efficiency.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffect of Diffuser Inlet Angles on the Power and Torque Coefficients of a Hydrokinetic Turbine
    typeJournal Paper
    journal volume148
    journal issue1
    journal titleJournal of Offshore Mechanics and Arctic Engineering
    identifier doi10.1115/1.4069635
    treeJournal of Offshore Mechanics and Arctic Engineering:;2026:;volume( 148 ):;issue:001
    contenttypeFulltext