    Temperature Stability Analysis of Adjustable Operating Temperature Loop Heat Pipe

    Source: ASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:001::page 138
    Author:
    Fang, Zenong
    ,
    Liu, Lei
    ,
    Wang, Chuxin
    ,
    Wu, Qi
    ,
    Huang, Jinyin
    ,
    Wang, Ye
    ,
    Liu, Chang
    ,
    Liu, Sixue
    ,
    Zhang, Hongxing
    ,
    Miao, Jianyin
    DOI: 10.1115/1.4069399
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Loop heat pipes are widely applied in thermal management field of spacecraft payload, owing to the advantages of high temperature controlling accuracy, high heat transfer capability, long heat transfer distance, and minimal vibration. For the thermal control of spacecraft payload working intermittently with heat dissipation changing dramatically, the adjustable operating temperature loop heat pipe was proposed and analyzed in this paper. The adjustable operating temperature loop heat pipe was found to save preservation heating power enormously when payload was turned off. To decrease the temperature overshoot when temperature setpoint was adjusted, the influence of temperature controlling point's location and heating mode were investigated. A heat leak model was established to predict compensation chamber heating power. High temperature controlling accuracy was realized by using double heating loops and double temperature setpoints. The on-orbit data showed that the temperature controlling accuracy was higher than ±0.5 °C with preservation heating power reducing from 318 W to 47 W.
    • Download: (1.585Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Temperature Stability Analysis of Adjustable Operating Temperature Loop Heat Pipe

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4315310
    Collections
    • ASME Journal of Heat and Mass Transfer

    Show full item record

    contributor authorFang, Zenong
    contributor authorLiu, Lei
    contributor authorWang, Chuxin
    contributor authorWu, Qi
    contributor authorHuang, Jinyin
    contributor authorWang, Ye
    contributor authorLiu, Chang
    contributor authorLiu, Sixue
    contributor authorZhang, Hongxing
    contributor authorMiao, Jianyin
    date accessioned2026-08-23T07:35:10Z
    date available2026-08-23T07:35:10Z
    date copyright2026/01/01
    date issued2026
    identifier issn2832-8450
    identifier otherht-25-1194.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315310
    description abstractAbstract. Loop heat pipes are widely applied in thermal management field of spacecraft payload, owing to the advantages of high temperature controlling accuracy, high heat transfer capability, long heat transfer distance, and minimal vibration. For the thermal control of spacecraft payload working intermittently with heat dissipation changing dramatically, the adjustable operating temperature loop heat pipe was proposed and analyzed in this paper. The adjustable operating temperature loop heat pipe was found to save preservation heating power enormously when payload was turned off. To decrease the temperature overshoot when temperature setpoint was adjusted, the influence of temperature controlling point's location and heating mode were investigated. A heat leak model was established to predict compensation chamber heating power. High temperature controlling accuracy was realized by using double heating loops and double temperature setpoints. The on-orbit data showed that the temperature controlling accuracy was higher than ±0.5 °C with preservation heating power reducing from 318 W to 47 W.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTemperature Stability Analysis of Adjustable Operating Temperature Loop Heat Pipe
    typeJournal Paper
    journal volume148
    journal issue1
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4069399
    journal fristpage138
    journal lastpage143
    page6
    treeASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian