YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Tribology
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Tribology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Tribological Performance of Magnetorheological Fluid in Compliant Contact

    Source: Journal of Tribology:;2026:;volume( 148 ):;issue:006
    Author:
    Jiří, Žáček
    ,
    Zbyněk, Strecker
    ,
    Filip, Jeniš
    ,
    Ondřej, Macháček
    ,
    Radoslav, Bajza
    ,
    Michal, Kubík
    DOI: 10.1115/1.4070824
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. The current challenge with magnetorheological (MR) damper technology lies in its limited durability, primarily due to the abrasive nature of ferromagnetic particles. The critical component appears to be the seal, representing a soft contact. This comparative study focuses on testing the friction coefficient (COF) and wear loss of compliant contacts immersed in magnetorheological fluid. This article presents wear loss and the coefficient of friction for six selected sealing materials flooded by MR fluid. Furthermore, the effect of particle concentration on wear loss is also tested. Finally, the effect of long-term loading of MR fluid on tribological properties is presented. The results show that the polyurethane-based sealing material exhibited the lowest wear, while polytetrafluoroethylene (PTFE) exhibited the lowest COF. Polyurethane materials were found to be approximately 3.5 times more resistant to abrasion than nitrile butadiene rubber seals and 2.5 times more resistant than PTFE. The concentration of particles in MR fluids within the tested range (22–40 vol%) did not significantly affect abrasiveness. It was found that MR fluid subjected to long-term mechanical loading exhibited nearly a threefold increase in abrasiveness compared to new MR fluid. Consequently, it can be concluded that long-term mechanical loading of MR fluid has a substantial impact on its tribological properties. However, a more detailed study of tribological properties changes with long-term loading is the subject of further research.
    • Download: (1.528Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Tribological Performance of Magnetorheological Fluid in Compliant Contact

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4314834
    Collections
    • Journal of Tribology

    Show full item record

    contributor authorJiří, Žáček
    contributor authorZbyněk, Strecker
    contributor authorFilip, Jeniš
    contributor authorOndřej, Macháček
    contributor authorRadoslav, Bajza
    contributor authorMichal, Kubík
    date accessioned2026-08-23T07:14:58Z
    date available2026-08-23T07:14:58Z
    date copyright2026/06/01
    date issued2026
    identifier issn0742-4787
    identifier othertrib-25-1564.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4314834
    description abstractAbstract. The current challenge with magnetorheological (MR) damper technology lies in its limited durability, primarily due to the abrasive nature of ferromagnetic particles. The critical component appears to be the seal, representing a soft contact. This comparative study focuses on testing the friction coefficient (COF) and wear loss of compliant contacts immersed in magnetorheological fluid. This article presents wear loss and the coefficient of friction for six selected sealing materials flooded by MR fluid. Furthermore, the effect of particle concentration on wear loss is also tested. Finally, the effect of long-term loading of MR fluid on tribological properties is presented. The results show that the polyurethane-based sealing material exhibited the lowest wear, while polytetrafluoroethylene (PTFE) exhibited the lowest COF. Polyurethane materials were found to be approximately 3.5 times more resistant to abrasion than nitrile butadiene rubber seals and 2.5 times more resistant than PTFE. The concentration of particles in MR fluids within the tested range (22–40 vol%) did not significantly affect abrasiveness. It was found that MR fluid subjected to long-term mechanical loading exhibited nearly a threefold increase in abrasiveness compared to new MR fluid. Consequently, it can be concluded that long-term mechanical loading of MR fluid has a substantial impact on its tribological properties. However, a more detailed study of tribological properties changes with long-term loading is the subject of further research.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTribological Performance of Magnetorheological Fluid in Compliant Contact
    typeJournal Paper
    journal volume148
    journal issue6
    journal titleJournal of Tribology
    identifier doi10.1115/1.4070824
    treeJournal of Tribology:;2026:;volume( 148 ):;issue:006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian