    Archive

    Experimental Investigation of a 12-Turn High-Temperature Oscillating Heat Pipe

    Source: ASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:006::page 47
    Author:
    Hoelle, James
    ,
    Baalmann, Samantha
    ,
    Ibrahim, Omar
    ,
    Nunez, Roberto
    ,
    Ma, Hongbin
    ,
    Miller, Alex
    DOI: 10.1115/1.4071398
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Oscillating heat pipes (OHPs) can efficiently transfer heat through the thermally excited oscillation and phase change heat transfer within sealed, capillary-sized channels. The working fluid capable of effective evaporation and condensation plays a critical role in the OHP performance, directly influencing its thermal stability and heat transfer performance. A 12-turn high-temperature oscillating heat pipe (HTOHP) charged with liquid metal, NaK (78% K), and a total length of 609.6 mm was fabricated and tested. The HTOHP was made from stainless-steel 316 tubing with an inner diameter of 3.05 mm and an outer diameter of 6.35 mm. The charged HTOHP was placed inside of a stainless-steel test chamber to (1) enclose the system to combat radiative heat influence; and (2) allow the HTOHP to be rotated to determine the inclination angle effect on the heat transfer performance of the HTOHP. The heat inputs tested for the HTOHP ranged from 500 to 3250 W for inclination angles of −30 deg, 0 deg, 30 deg, 60 deg, and 90 deg. Experimental results show that heat transfer performance in an HTOHP significantly depended on the power input and the inclination angle. Results show that a 12-turn tubular OHP can transfer a power up to 3250 W for which the coolant temperature of the OHP condenser was 334 °C and the evaporator temperature was 906 °C. The heat transfer performance observed under these conditions is roughly 100 times better than stainless steel on its own.
    • Download: (1.606Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental Investigation of a 12-Turn High-Temperature Oscillating Heat Pipe

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4314804
    Collections
    • ASME Journal of Heat and Mass Transfer

    Show full item record

    contributor authorHoelle, James
    contributor authorBaalmann, Samantha
    contributor authorIbrahim, Omar
    contributor authorNunez, Roberto
    contributor authorMa, Hongbin
    contributor authorMiller, Alex
    date accessioned2026-08-23T07:13:49Z
    date available2026-08-23T07:13:49Z
    date copyright2026/06/01
    date issued2026
    identifier issn2832-8450
    identifier otherht-25-1444.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4314804
    description abstractAbstract. Oscillating heat pipes (OHPs) can efficiently transfer heat through the thermally excited oscillation and phase change heat transfer within sealed, capillary-sized channels. The working fluid capable of effective evaporation and condensation plays a critical role in the OHP performance, directly influencing its thermal stability and heat transfer performance. A 12-turn high-temperature oscillating heat pipe (HTOHP) charged with liquid metal, NaK (78% K), and a total length of 609.6 mm was fabricated and tested. The HTOHP was made from stainless-steel 316 tubing with an inner diameter of 3.05 mm and an outer diameter of 6.35 mm. The charged HTOHP was placed inside of a stainless-steel test chamber to (1) enclose the system to combat radiative heat influence; and (2) allow the HTOHP to be rotated to determine the inclination angle effect on the heat transfer performance of the HTOHP. The heat inputs tested for the HTOHP ranged from 500 to 3250 W for inclination angles of −30 deg, 0 deg, 30 deg, 60 deg, and 90 deg. Experimental results show that heat transfer performance in an HTOHP significantly depended on the power input and the inclination angle. Results show that a 12-turn tubular OHP can transfer a power up to 3250 W for which the coolant temperature of the OHP condenser was 334 °C and the evaporator temperature was 906 °C. The heat transfer performance observed under these conditions is roughly 100 times better than stainless steel on its own.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Investigation of a 12-Turn High-Temperature Oscillating Heat Pipe
    typeJournal Paper
    journal volume148
    journal issue6
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4071398
    journal fristpage47
    journal lastpage67
    page21
    treeASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian