    Estimation of Temperature Rise in Magnetorheological Fluid-Based Finishing of Thin Substrate: A Theoretical and Experimental Study

    Source: Journal of Manufacturing Science and Engineering:;2024:;volume( 147 ):;issue: 002::page 21003-1
    Author:
    Dubey, Nitesh Kumar
    ,
    Sidpara, Ajay
    DOI: 10.1115/1.4066439
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Magnetorheological finishing (MRF) is used to precisely finish various materials such as hard crystals, optical, and brittle materials. In this paper, the thermal behavior of the MRF process is studied theoretically and experimentally on thin copper substrate surface by varying rotational speed and working gap. The wall shear stress (WSS) represents the frictional force per unit area exerted by the flowing magnetorheological (MR) fluid on the workpiece surface and it is determined using three-dimensional computational fluid dynamics numerical simulations that use a dynamic viscosity model based on the variable magnetic flux density. A thermal model is proposed to predict heat generation and temperature rise on the workpiece surface with the help of energy partitioning, heat conduction equations, and WSS. It is observed that the temperature rises with increasing the rotational speed and reducing the working gap. Considering MR fluid with only abrasive particles, the theoretical temperature rise of 21.32 °C was predicted. When MR fluid is with carbonyl iron particles and abrasive particles, the theoretical temperature rise was 19.37 °C. In experiments, the maximum temperature rise of 14.8 °C was obtained. Finite element analysis is performed to estimate magnetic flux density variation on the workpiece surface and viscosity variation over the workpiece surface. Surface roughness (Sa) reduced from an initial value of 0.236 µm to 0.079 µm at 600 rpm tool rotational speed and 3 mm working gap.
    • Download: (1.895Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Estimation of Temperature Rise in Magnetorheological Fluid-Based Finishing of Thin Substrate: A Theoretical and Experimental Study

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4305384
    Collections
    • Journal of Manufacturing Science and Engineering

    Show full item record

    contributor authorDubey, Nitesh Kumar
    contributor authorSidpara, Ajay
    date accessioned2025-04-21T10:02:46Z
    date available2025-04-21T10:02:46Z
    date copyright10/4/2024 12:00:00 AM
    date issued2024
    identifier issn1087-1357
    identifier othermanu_147_2_021003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4305384
    description abstractMagnetorheological finishing (MRF) is used to precisely finish various materials such as hard crystals, optical, and brittle materials. In this paper, the thermal behavior of the MRF process is studied theoretically and experimentally on thin copper substrate surface by varying rotational speed and working gap. The wall shear stress (WSS) represents the frictional force per unit area exerted by the flowing magnetorheological (MR) fluid on the workpiece surface and it is determined using three-dimensional computational fluid dynamics numerical simulations that use a dynamic viscosity model based on the variable magnetic flux density. A thermal model is proposed to predict heat generation and temperature rise on the workpiece surface with the help of energy partitioning, heat conduction equations, and WSS. It is observed that the temperature rises with increasing the rotational speed and reducing the working gap. Considering MR fluid with only abrasive particles, the theoretical temperature rise of 21.32 °C was predicted. When MR fluid is with carbonyl iron particles and abrasive particles, the theoretical temperature rise was 19.37 °C. In experiments, the maximum temperature rise of 14.8 °C was obtained. Finite element analysis is performed to estimate magnetic flux density variation on the workpiece surface and viscosity variation over the workpiece surface. Surface roughness (Sa) reduced from an initial value of 0.236 µm to 0.079 µm at 600 rpm tool rotational speed and 3 mm working gap.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEstimation of Temperature Rise in Magnetorheological Fluid-Based Finishing of Thin Substrate: A Theoretical and Experimental Study
    typeJournal Paper
    journal volume147
    journal issue2
    journal titleJournal of Manufacturing Science and Engineering
    identifier doi10.1115/1.4066439
    journal fristpage21003-1
    journal lastpage21003-14
    page14
    treeJournal of Manufacturing Science and Engineering:;2024:;volume( 147 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian