YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Design and Construction Practice
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Design and Construction Practice
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Modeling of Column Shear Hinges in Pushover Analysis and Experimental Validation

    Source: Practice Periodical on Structural Design and Construction:;2024:;Volume ( 029 ):;issue: 003::page 04024024-1
    Author:
    Komathi Murugan
    ,
    Amlan Kumar Sengupta
    DOI: 10.1061/PPSCFX.SCENG-1341
    Publisher: American Society of Civil Engineers
    Abstract: A column is a critical member in a reinforced concrete framed building. It transfers lateral shear during an earthquake, in the presence of gravity loads. Failure of short wall-type shear-critical columns in the soft and weak open ground story (OGS) of a building during an earthquake can trigger pancake-type collapse. To avoid these types of failures, the weak columns in the OGS can be strengthened locally, in addition to a global retrofit strategy applied to the entire structure. This research focuses on the seismic strengthening of such short columns using the concrete jacketing technique. The study presented in this paper demonstrates a methodology to model the shear behavior of short columns before and after jacketing. This pertains to the nonlinear static analysis of a building under lateral loads, such as a static pushover analysis. The development of shear hinge properties for as-built and jacketed short columns is presented in this paper. These were based on a proposed generalized truss analogy, which was validated based on the tests of column specimens conducted as part of this research. Pushover analyses of a building model without and with jacketed columns in the OGS were conducted. Selected results of the analyses are presented in this paper. The modeling of the shear hinge properties for the short columns in the OGS demonstrated the brittle behavior under lateral loads before jacketing and the improvement in ductility after jacketing. The proposed method can be used in professional practice for evaluating buildings with short columns strengthened by concrete jacketing. Since all the columns in a story cannot be jacketed due to economic and functional considerations, the effect of selective jacketing of the columns on the behavior of the building under lateral loads is illustrated. An existing reinforced concrete framed building can be retrofitted to mitigate the damage expected during a future earthquake. The effect of retrofit on the structure should be justified preferably by a nonlinear method of analysis such as pushover analysis. The primary input in such an analysis is the nonlinear behavior of each structural member under increasing lateral loads, modeled as the hinge property. The presented study discusses the pushover analyses of a building, before and after strengthening its short wall-type columns in the open ground story by concrete jacketing. A method to develop the shear hinge properties of as-built and jacketed short columns is explained in this paper. The method is based on extending the truss analogy for modeling the shear deformation of a short frame member after the diagonal cracking of concrete in the web. The procedure does not need any special purpose program for calculation and can be implemented using a spreadsheet. Also, a parametric study on optimum strengthening is presented, showing the effect of jacketing selected columns, as all the columns need not be intervened, to reduce the cost as well as the disruption to the users.
    • Download: (3.936Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Modeling of Column Shear Hinges in Pushover Analysis and Experimental Validation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4298440
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorKomathi Murugan
    contributor authorAmlan Kumar Sengupta
    date accessioned2024-12-24T10:10:46Z
    date available2024-12-24T10:10:46Z
    date copyright8/1/2024 12:00:00 AM
    date issued2024
    identifier otherPPSCFX.SCENG-1341.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4298440
    description abstractA column is a critical member in a reinforced concrete framed building. It transfers lateral shear during an earthquake, in the presence of gravity loads. Failure of short wall-type shear-critical columns in the soft and weak open ground story (OGS) of a building during an earthquake can trigger pancake-type collapse. To avoid these types of failures, the weak columns in the OGS can be strengthened locally, in addition to a global retrofit strategy applied to the entire structure. This research focuses on the seismic strengthening of such short columns using the concrete jacketing technique. The study presented in this paper demonstrates a methodology to model the shear behavior of short columns before and after jacketing. This pertains to the nonlinear static analysis of a building under lateral loads, such as a static pushover analysis. The development of shear hinge properties for as-built and jacketed short columns is presented in this paper. These were based on a proposed generalized truss analogy, which was validated based on the tests of column specimens conducted as part of this research. Pushover analyses of a building model without and with jacketed columns in the OGS were conducted. Selected results of the analyses are presented in this paper. The modeling of the shear hinge properties for the short columns in the OGS demonstrated the brittle behavior under lateral loads before jacketing and the improvement in ductility after jacketing. The proposed method can be used in professional practice for evaluating buildings with short columns strengthened by concrete jacketing. Since all the columns in a story cannot be jacketed due to economic and functional considerations, the effect of selective jacketing of the columns on the behavior of the building under lateral loads is illustrated. An existing reinforced concrete framed building can be retrofitted to mitigate the damage expected during a future earthquake. The effect of retrofit on the structure should be justified preferably by a nonlinear method of analysis such as pushover analysis. The primary input in such an analysis is the nonlinear behavior of each structural member under increasing lateral loads, modeled as the hinge property. The presented study discusses the pushover analyses of a building, before and after strengthening its short wall-type columns in the open ground story by concrete jacketing. A method to develop the shear hinge properties of as-built and jacketed short columns is explained in this paper. The method is based on extending the truss analogy for modeling the shear deformation of a short frame member after the diagonal cracking of concrete in the web. The procedure does not need any special purpose program for calculation and can be implemented using a spreadsheet. Also, a parametric study on optimum strengthening is presented, showing the effect of jacketing selected columns, as all the columns need not be intervened, to reduce the cost as well as the disruption to the users.
    publisherAmerican Society of Civil Engineers
    titleModeling of Column Shear Hinges in Pushover Analysis and Experimental Validation
    typeJournal Article
    journal volume29
    journal issue3
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/PPSCFX.SCENG-1341
    journal fristpage04024024-1
    journal lastpage04024024-17
    page17
    treePractice Periodical on Structural Design and Construction:;2024:;Volume ( 029 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian