    Shock Wave Evaluation in Shell and Tube Heat Exchanger Tube Rupture Scenario

    Source: Journal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 004::page 41007-1
    Author:
    Terenzi, Alessandro
    DOI: 10.1115/1.4064588
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Shell and Tube Heat Exchangers (STHEs) are commonly used in oil and gas plants to cool or heat process fluids. A possible issue when designing such systems is represented by the tube rupture scenario, when the internal HP (high-pressure) fluid is suddenly discharged to the LP (low-pressure) fluid in the shell. Since, usually, the tube and shell sides have different design pressures, this scenario must be analyzed to assess if the safety measures are fit to protect the weakest part of the system. The time evolution of this event is characterized by different phases; in the first one, a shock wave is generated and propagated very rapidly in the system, with a time scale in the order of a few ms. The phenomenon is so rapid that pressure relief devices are not effective. This kind of wave is normally not evaluated in the majority of available publications; however, it is deemed that it is of particular relevance for large-size SHTEs, due to their significant investment cost, and hence, a methodology has been developed in this work for the purpose. The main impact of such waves is expected in the LP piping connected to the exchanger. The amplitude of the shock wave at the source location, i.e., at the ruptured tube, is calculated based on the theory of the Riemann problem, with reference to different types of HP and LP fluids. Then, the relevant propagation up to the piping entrance is studied to estimate the wave damping and the effective wave amplitude impacting it. Both validation calculations and calculations referred to new design applications and existing installations are presented, and possible mitigation measures are proposed, if any.
    • Download: (723.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Shock Wave Evaluation in Shell and Tube Heat Exchanger Tube Rupture Scenario

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4295918
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorTerenzi, Alessandro
    date accessioned2024-04-24T22:48:40Z
    date available2024-04-24T22:48:40Z
    date copyright2/19/2024 12:00:00 AM
    date issued2024
    identifier issn1948-5085
    identifier othertsea_16_4_041007.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295918
    description abstractShell and Tube Heat Exchangers (STHEs) are commonly used in oil and gas plants to cool or heat process fluids. A possible issue when designing such systems is represented by the tube rupture scenario, when the internal HP (high-pressure) fluid is suddenly discharged to the LP (low-pressure) fluid in the shell. Since, usually, the tube and shell sides have different design pressures, this scenario must be analyzed to assess if the safety measures are fit to protect the weakest part of the system. The time evolution of this event is characterized by different phases; in the first one, a shock wave is generated and propagated very rapidly in the system, with a time scale in the order of a few ms. The phenomenon is so rapid that pressure relief devices are not effective. This kind of wave is normally not evaluated in the majority of available publications; however, it is deemed that it is of particular relevance for large-size SHTEs, due to their significant investment cost, and hence, a methodology has been developed in this work for the purpose. The main impact of such waves is expected in the LP piping connected to the exchanger. The amplitude of the shock wave at the source location, i.e., at the ruptured tube, is calculated based on the theory of the Riemann problem, with reference to different types of HP and LP fluids. Then, the relevant propagation up to the piping entrance is studied to estimate the wave damping and the effective wave amplitude impacting it. Both validation calculations and calculations referred to new design applications and existing installations are presented, and possible mitigation measures are proposed, if any.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleShock Wave Evaluation in Shell and Tube Heat Exchanger Tube Rupture Scenario
    typeJournal Paper
    journal volume16
    journal issue4
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4064588
    journal fristpage41007-1
    journal lastpage41007-12
    page12
    treeJournal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian