Experimental Study of Thermal Hydraulic Performance Improvement in Solar Air Heater Channel With V-Shaped Porous BafflesSource: Journal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 011::page 111007-1DOI: 10.1115/1.4063043Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Experiments have been conducted to determine how several geometrical parameters of V-shaped porous baffles influence flow characteristics and heat transfer in a rectangular channel. Experiments were conducted on geometric parameters, namely, a relative baffle height (e/H) of 0.4–1, a relative baffle pitch (P/e) of 3–6, open area ratio values of 21–34%, and a single attack angle (α) of 60 deg. Using Reynolds numbers ranging from 2500 to 12,000, V-shaped porous baffles have been examined. Based on a relative baffle pitch of 5, a relative baffle height of 1, and an open area ratio of 21%, the maximum increases in the Nusselt number (Nu) and friction factor (f) were 2.84 and 7 times, respectively. A maximum value of 1.69 is found at e/H = 0.40, P/e = 6, and b = 34% for the thermo-hydraulic performance parameter. Correlations for (Nu) and (f) are developed as functions of P/e, e/H, and Re.
|
Show full item record
| contributor author | Baissi, M.T. | |
| contributor author | Hassani, S. | |
| contributor author | Karoua, Housseyn | |
| contributor author | Aoues, K. | |
| contributor author | Moummi, N. | |
| date accessioned | 2023-11-29T19:43:07Z | |
| date available | 2023-11-29T19:43:07Z | |
| date copyright | 8/16/2023 12:00:00 AM | |
| date issued | 8/16/2023 12:00:00 AM | |
| date issued | 2023-08-16 | |
| identifier issn | 1948-5085 | |
| identifier other | tsea_15_11_111007.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4294976 | |
| description abstract | Experiments have been conducted to determine how several geometrical parameters of V-shaped porous baffles influence flow characteristics and heat transfer in a rectangular channel. Experiments were conducted on geometric parameters, namely, a relative baffle height (e/H) of 0.4–1, a relative baffle pitch (P/e) of 3–6, open area ratio values of 21–34%, and a single attack angle (α) of 60 deg. Using Reynolds numbers ranging from 2500 to 12,000, V-shaped porous baffles have been examined. Based on a relative baffle pitch of 5, a relative baffle height of 1, and an open area ratio of 21%, the maximum increases in the Nusselt number (Nu) and friction factor (f) were 2.84 and 7 times, respectively. A maximum value of 1.69 is found at e/H = 0.40, P/e = 6, and b = 34% for the thermo-hydraulic performance parameter. Correlations for (Nu) and (f) are developed as functions of P/e, e/H, and Re. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Experimental Study of Thermal Hydraulic Performance Improvement in Solar Air Heater Channel With V-Shaped Porous Baffles | |
| type | Journal Paper | |
| journal volume | 15 | |
| journal issue | 11 | |
| journal title | Journal of Thermal Science and Engineering Applications | |
| identifier doi | 10.1115/1.4063043 | |
| journal fristpage | 111007-1 | |
| journal lastpage | 111007-10 | |
| page | 10 | |
| tree | Journal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 011 | |
| contenttype | Fulltext |