    Seismic Control of Story Isolation System Using Tuned Mass Damper Inerter

    Source: Journal of Engineering Mechanics:;2022:;Volume ( 149 ):;issue: 003::page 04022116-1
    Author:
    Qigang Liang
    ,
    Jinyuan Wei
    ,
    Luyu Li
    DOI: 10.1061/JENMDT.EMENG-6850
    Publisher: ASCE
    Abstract: Story isolation systems (SIS) have great application potential in the seismic design of some special structures. This paper studied the seismic control performance of SIS using a tuned mass damper inerter (TMDI) considering two installation modes, namely TMDI-A and TMDI-B. First, a four-degree-of-freedom (4DOF) simplified model including the masses of the substructure, superstructure, isolation layer, and TMDI is proposed, and three cases with different isolation layer locations were designed. Second, numerical optimization based on the H2 norm was used to obtain the optimal parameters of the TMDI considering the influence of the tuned mass ratio and the design period and damping of the isolation layer. Third, a comparative study was conducted on the optimal performance of the TMDI-A and TMDI-B schemes compared with their corresponding tuned mass damper (TMD) schemes (i.e., TMD-A and TMD-B) by time-history analysis. Finally, an 11-story SIS was designed as an example to investigate the effectiveness of the TMDI in a multistory structure. Results showed that the optimal performance of the two TMDI schemes can be significantly enhanced with the increase of the inertance–mass ratio, and also will be improved with the rise of the isolation layer location, whereas the increase of the tuned mass ratio had a converse effect on the performance of TMDI-A and TMDI-B. In addition, both TMDI schemes had better performance when the isolation layer was in a low-damping state, and the isolated period of the superstructure only affected the control performance of the TMDI-B scheme. In summary, the TMDI schemes had remarkable superiority over the TMD schemes, and TMDI-B had better performance than the TMDI-A scheme, which was verified by the analysis of the simplified model and the multistory structure.
    • Download: (1.182Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Seismic Control of Story Isolation System Using Tuned Mass Damper Inerter

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4293480
    Collections
    • Journal of Engineering Mechanics

    Show full item record

    contributor authorQigang Liang
    contributor authorJinyuan Wei
    contributor authorLuyu Li
    date accessioned2023-11-27T23:19:33Z
    date available2023-11-27T23:19:33Z
    date issued12/23/2022 12:00:00 AM
    identifier otherJENMDT.EMENG-6850.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4293480
    description abstractStory isolation systems (SIS) have great application potential in the seismic design of some special structures. This paper studied the seismic control performance of SIS using a tuned mass damper inerter (TMDI) considering two installation modes, namely TMDI-A and TMDI-B. First, a four-degree-of-freedom (4DOF) simplified model including the masses of the substructure, superstructure, isolation layer, and TMDI is proposed, and three cases with different isolation layer locations were designed. Second, numerical optimization based on the H2 norm was used to obtain the optimal parameters of the TMDI considering the influence of the tuned mass ratio and the design period and damping of the isolation layer. Third, a comparative study was conducted on the optimal performance of the TMDI-A and TMDI-B schemes compared with their corresponding tuned mass damper (TMD) schemes (i.e., TMD-A and TMD-B) by time-history analysis. Finally, an 11-story SIS was designed as an example to investigate the effectiveness of the TMDI in a multistory structure. Results showed that the optimal performance of the two TMDI schemes can be significantly enhanced with the increase of the inertance–mass ratio, and also will be improved with the rise of the isolation layer location, whereas the increase of the tuned mass ratio had a converse effect on the performance of TMDI-A and TMDI-B. In addition, both TMDI schemes had better performance when the isolation layer was in a low-damping state, and the isolated period of the superstructure only affected the control performance of the TMDI-B scheme. In summary, the TMDI schemes had remarkable superiority over the TMD schemes, and TMDI-B had better performance than the TMDI-A scheme, which was verified by the analysis of the simplified model and the multistory structure.
    publisherASCE
    titleSeismic Control of Story Isolation System Using Tuned Mass Damper Inerter
    typeJournal Article
    journal volume149
    journal issue3
    journal titleJournal of Engineering Mechanics
    identifier doi10.1061/JENMDT.EMENG-6850
    journal fristpage04022116-1
    journal lastpage04022116-13
    page13
    treeJournal of Engineering Mechanics:;2022:;Volume ( 149 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian