    In-Plane Loading Tests and a Retrofitting Technique for Masonry Infill Panels in RC Frames with Eccentric Openings

    Source: Journal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 011::page 04022183
    Author:
    Yi-Hsuan Tu
    ,
    I-Ting Tung
    ,
    Tsung-Chih Chiou
    DOI: 10.1061/(ASCE)ST.1943-541X.0003481
    Publisher: ASCE
    Abstract: The use of masonry infills in reinforced concrete (RC)-framed structures implicates the strength of the frame and the seismic resistance of the building. The present study (1) experimentally investigated the behavior of masonry infill panels surrounded by RC frames with eccentric door openings, (2) proposed and evaluated a retrofitting method based on the experimental results, and (3) introduced an analytical masonry infill model that is currently used in seismic assessment for RC buildings in Taiwan. This study’s retrofitting method centers on improving the confinement at the opening edge only instead of reinforcing the panel itself. Compared with existing methods, this method entails a lower retrofitting cost because a smaller area needs to be retrofitted. In experiments, the method notably improved the lateral resistance, where retrofitting yielded a 68% and 120% increase in strength in the push and pull directions, respectively. The confinement provided by the retrofit elements (1) allowed the damage on the panel to develop gradually; and (2) maintained the integrity of the panel during the test. Consequently, the drift at maximum strength significantly increased, and the panel could provide higher residual strength after a peak in strength. Although the deformation capacity was not improved because the retrofitting method did not alter the behavior of the columns, retrofitting yielded better energy dissipation due to a higher residual strength. Furthermore, the analytical masonry infill model generally agreed with the experimental data, although the displacements where the maximum strength occurred were underestimated and overestimated in the specimens with and without retrofitting, respectively.
    • Download: (5.756Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      In-Plane Loading Tests and a Retrofitting Technique for Masonry Infill Panels in RC Frames with Eccentric Openings

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4289396
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorYi-Hsuan Tu
    contributor authorI-Ting Tung
    contributor authorTsung-Chih Chiou
    date accessioned2023-04-07T00:36:57Z
    date available2023-04-07T00:36:57Z
    date issued2022/11/01
    identifier other%28ASCE%29ST.1943-541X.0003481.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4289396
    description abstractThe use of masonry infills in reinforced concrete (RC)-framed structures implicates the strength of the frame and the seismic resistance of the building. The present study (1) experimentally investigated the behavior of masonry infill panels surrounded by RC frames with eccentric door openings, (2) proposed and evaluated a retrofitting method based on the experimental results, and (3) introduced an analytical masonry infill model that is currently used in seismic assessment for RC buildings in Taiwan. This study’s retrofitting method centers on improving the confinement at the opening edge only instead of reinforcing the panel itself. Compared with existing methods, this method entails a lower retrofitting cost because a smaller area needs to be retrofitted. In experiments, the method notably improved the lateral resistance, where retrofitting yielded a 68% and 120% increase in strength in the push and pull directions, respectively. The confinement provided by the retrofit elements (1) allowed the damage on the panel to develop gradually; and (2) maintained the integrity of the panel during the test. Consequently, the drift at maximum strength significantly increased, and the panel could provide higher residual strength after a peak in strength. Although the deformation capacity was not improved because the retrofitting method did not alter the behavior of the columns, retrofitting yielded better energy dissipation due to a higher residual strength. Furthermore, the analytical masonry infill model generally agreed with the experimental data, although the displacements where the maximum strength occurred were underestimated and overestimated in the specimens with and without retrofitting, respectively.
    publisherASCE
    titleIn-Plane Loading Tests and a Retrofitting Technique for Masonry Infill Panels in RC Frames with Eccentric Openings
    typeJournal Article
    journal volume148
    journal issue11
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003481
    journal fristpage04022183
    journal lastpage04022183_15
    page15
    treeJournal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian