    Archive

    Evaluation of Clinical and Technical Parameters to Customize Total Knee Arthroplasty Implants

    Source: Journal of Computing and Information Science in Engineering:;2022:;volume( 022 ):;issue: 006::page 61006
    Author:
    Ghidotti, Anna;Landi, Daniele;Regazzoni, Daniele;Rizzi, Caterina
    DOI: 10.1115/1.4055427
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Since every structure in the human body can vary, customization is important to choose the most appropriate medical option according to the patient. Total knee arthroplasty (TKA) is a surgical procedure for the knee replacement that has a high rate of patient’s dissatisfaction. Indeed, conventional prostheses are based on anthropometric data that accommodate common knees. However, mismatch can occur due to anatomical variations among the individuals. Thanks to the advances in imaging techniques and 3D modeling, it is possible to create customized knee implants starting from medical images. In this context, the present research proposes a methodology to design a customized knee implant taking into account clinical (e.g., prosthesis alignment and surgical cuts) and technical parameters (e.g., materials) that have a direct impact on TKA performance and patient’s satisfaction. Changing these parameters, different scenarios have been modeled and simulated to understand the most suitable combination. Finite element analysis (FEA) has been employed to simulate and compare the proposed customized models, changing the different clinical and technical parameters. Stress induced by different combinations of the parameters has been evaluated to choose the optimal solution among the eight proposed scenarios. The optimum is reached with a physiological alignment, with six femoral facets and the ultra-high molecular weight polyethylene (UHMWPE) tibial insert. The implant design maintains the natural joint line and allows preserving more bone. The material is the parameter that mostly influences the stress distribution.
    • Download: (669.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Evaluation of Clinical and Technical Parameters to Customize Total Knee Arthroplasty Implants

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4288119
    Collections
    • Journal of Computing and Information Science in Engineering

    Show full item record

    contributor authorGhidotti, Anna;Landi, Daniele;Regazzoni, Daniele;Rizzi, Caterina
    date accessioned2022-12-27T23:12:44Z
    date available2022-12-27T23:12:44Z
    date copyright9/15/2022 12:00:00 AM
    date issued2022
    identifier issn1530-9827
    identifier otherjcise_22_6_061006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4288119
    description abstractSince every structure in the human body can vary, customization is important to choose the most appropriate medical option according to the patient. Total knee arthroplasty (TKA) is a surgical procedure for the knee replacement that has a high rate of patient’s dissatisfaction. Indeed, conventional prostheses are based on anthropometric data that accommodate common knees. However, mismatch can occur due to anatomical variations among the individuals. Thanks to the advances in imaging techniques and 3D modeling, it is possible to create customized knee implants starting from medical images. In this context, the present research proposes a methodology to design a customized knee implant taking into account clinical (e.g., prosthesis alignment and surgical cuts) and technical parameters (e.g., materials) that have a direct impact on TKA performance and patient’s satisfaction. Changing these parameters, different scenarios have been modeled and simulated to understand the most suitable combination. Finite element analysis (FEA) has been employed to simulate and compare the proposed customized models, changing the different clinical and technical parameters. Stress induced by different combinations of the parameters has been evaluated to choose the optimal solution among the eight proposed scenarios. The optimum is reached with a physiological alignment, with six femoral facets and the ultra-high molecular weight polyethylene (UHMWPE) tibial insert. The implant design maintains the natural joint line and allows preserving more bone. The material is the parameter that mostly influences the stress distribution.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEvaluation of Clinical and Technical Parameters to Customize Total Knee Arthroplasty Implants
    typeJournal Paper
    journal volume22
    journal issue6
    journal titleJournal of Computing and Information Science in Engineering
    identifier doi10.1115/1.4055427
    journal fristpage61006
    journal lastpage61006_9
    page9
    treeJournal of Computing and Information Science in Engineering:;2022:;volume( 022 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian