    Design Synthesis of a Robotic Uniaxial Torque Device for Orthopedic Haptic Simulation

    Source: Journal of Medical Devices:;2022:;volume( 016 ):;issue: 003::page 31008-1
    Author:
    Cotter
    ,
    Trevor;Mongrain
    ,
    Rosaire;Driscoll
    ,
    Mark
    DOI: 10.1115/1.4054344
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Robotic devices are commonly used in surgical simulators to provide tactile, or haptic, feedback. They can provide customized feedback that can be rapidly modified with minimal hardware changes in comparison to nonrobotic systems. This work describes the design, development, and evaluation of one such tool: a novel uniaxial torque haptic device for a surgical training simulator. The objective of the work was to design a single connection haptic device that could augment an existing six degree-of-freedom haptic device to mimic a Concorde Clear vacuum curette. Design and evaluations focused on the tool's ability to deliver adequate torque, imitate a surgical tool, and be integrated into the haptic device. Twenty-nine surgeons tested the tool in the simulator and evaluated it via a questionnaire. The device was found to deliver the 800 N⋅mm of torque necessary to mimic an orthopedic procedure. Surgeons found it accurately imitated surgical tools physical appearance and maneuverability, scoring them 3.9 ± 1.0 and 3.3 ± 1.2, respectively, on a 1–5 Likert scale. By virtue of the functionality necessary for testing and evaluation, the device could be connected to the haptic device for mechanical and electrical engagement. This device is a step forward in the field of augmentable haptic devices for surgical simulation. By changing the number of robotically controlled degrees-of-freedom of a haptic device, existing devices can be tuned to meet the demands of a particular simulator, which has the potential to improve surgeon training standards.
    • Download: (1.034Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design Synthesis of a Robotic Uniaxial Torque Device for Orthopedic Haptic Simulation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4286975
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorCotter
    contributor authorTrevor;Mongrain
    contributor authorRosaire;Driscoll
    contributor authorMark
    date accessioned2022-08-18T12:51:16Z
    date available2022-08-18T12:51:16Z
    date copyright5/10/2022 12:00:00 AM
    date issued2022
    identifier issn1932-6181
    identifier othermed_016_03_031008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286975
    description abstractRobotic devices are commonly used in surgical simulators to provide tactile, or haptic, feedback. They can provide customized feedback that can be rapidly modified with minimal hardware changes in comparison to nonrobotic systems. This work describes the design, development, and evaluation of one such tool: a novel uniaxial torque haptic device for a surgical training simulator. The objective of the work was to design a single connection haptic device that could augment an existing six degree-of-freedom haptic device to mimic a Concorde Clear vacuum curette. Design and evaluations focused on the tool's ability to deliver adequate torque, imitate a surgical tool, and be integrated into the haptic device. Twenty-nine surgeons tested the tool in the simulator and evaluated it via a questionnaire. The device was found to deliver the 800 N⋅mm of torque necessary to mimic an orthopedic procedure. Surgeons found it accurately imitated surgical tools physical appearance and maneuverability, scoring them 3.9 ± 1.0 and 3.3 ± 1.2, respectively, on a 1–5 Likert scale. By virtue of the functionality necessary for testing and evaluation, the device could be connected to the haptic device for mechanical and electrical engagement. This device is a step forward in the field of augmentable haptic devices for surgical simulation. By changing the number of robotically controlled degrees-of-freedom of a haptic device, existing devices can be tuned to meet the demands of a particular simulator, which has the potential to improve surgeon training standards.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign Synthesis of a Robotic Uniaxial Torque Device for Orthopedic Haptic Simulation
    typeJournal Paper
    journal volume16
    journal issue3
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4054344
    journal fristpage31008-1
    journal lastpage31008-7
    page7
    treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian