    Optimization of Synthetic Vocal Fold Models for Glottal Closure

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2022:;volume( 005 ):;issue: 003::page 31106-1
    Author:
    Taylor
    ,
    Cassandra J.;Thomson
    ,
    Scott L.
    DOI: 10.1115/1.4054194
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Synthetic, self-oscillating models of the human vocal folds are used to study the complex and inter-related flow, structure, and acoustical aspects of voice production. The vocal folds typically collide during each cycle, thereby creating a brief period of glottal closure that has important implications for flow, acoustic, and motion-related outcomes. Many previous synthetic models, however, have been limited by incomplete glottal closure during vibration. In this study, a low-fidelity, two-dimensional, multilayer finite element model of vocal fold flow-induced vibration was coupled with a custom genetic algorithm optimization code to determine geometric and material characteristics that would be expected to yield physiologically-realistic frequency and closed quotient values. The optimization process yielded computational models that vibrated with favorable frequency and closed quotient characteristics. A tradeoff was observed between frequency and closed quotient. A synthetic, self-oscillating vocal fold model with geometric and material properties informed by the simulation outcomes was fabricated and tested for onset pressure, oscillation frequency, and closed quotient. The synthetic model successfully vibrated at a realistic frequency and exhibited a nonzero closed quotient. The methodology described in this study provides potential direction for fabricating synthetic models using isotropic silicone materials that can be designed to vibrate with physiologically-realistic frequencies and closed quotient values. The results also show the potential for a low-fidelity model optimization approach to be used to tune synthetic vocal fold model characteristics for specific vibratory outcomes.
    • Download: (2.134Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Optimization of Synthetic Vocal Fold Models for Glottal Closure

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4286943
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorTaylor
    contributor authorCassandra J.;Thomson
    contributor authorScott L.
    date accessioned2022-08-18T12:50:08Z
    date available2022-08-18T12:50:08Z
    date copyright4/27/2022 12:00:00 AM
    date issued2022
    identifier issn2572-7958
    identifier otherjesmdt_005_03_031106.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286943
    description abstractSynthetic, self-oscillating models of the human vocal folds are used to study the complex and inter-related flow, structure, and acoustical aspects of voice production. The vocal folds typically collide during each cycle, thereby creating a brief period of glottal closure that has important implications for flow, acoustic, and motion-related outcomes. Many previous synthetic models, however, have been limited by incomplete glottal closure during vibration. In this study, a low-fidelity, two-dimensional, multilayer finite element model of vocal fold flow-induced vibration was coupled with a custom genetic algorithm optimization code to determine geometric and material characteristics that would be expected to yield physiologically-realistic frequency and closed quotient values. The optimization process yielded computational models that vibrated with favorable frequency and closed quotient characteristics. A tradeoff was observed between frequency and closed quotient. A synthetic, self-oscillating vocal fold model with geometric and material properties informed by the simulation outcomes was fabricated and tested for onset pressure, oscillation frequency, and closed quotient. The synthetic model successfully vibrated at a realistic frequency and exhibited a nonzero closed quotient. The methodology described in this study provides potential direction for fabricating synthetic models using isotropic silicone materials that can be designed to vibrate with physiologically-realistic frequencies and closed quotient values. The results also show the potential for a low-fidelity model optimization approach to be used to tune synthetic vocal fold model characteristics for specific vibratory outcomes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOptimization of Synthetic Vocal Fold Models for Glottal Closure
    typeJournal Paper
    journal volume5
    journal issue3
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4054194
    journal fristpage31106-1
    journal lastpage31106-10
    page10
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2022:;volume( 005 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian