    Influences of Environmental Relative Humidity and Horizontal Scale of Subcloud Ascent on Deep Convective Initiation

    Source: Journal of the Atmospheric Sciences:;2022:;volume( 079 ):;issue: 002
    DOI: 10.1175/JAS-D-21-0056.1
    Abstract: This study examines two factors impacting initiation of moist deep convection: free-tropospheric environmental relative humidity (ϕE) and horizontal scale of subcloud ascent (Rsub), the latter exerting a dominant control on cumulus cloud width. A simple theoretical model is used to formulate a “scale selection” hypothesis: that a minimum Rsub is required for moist convection to go deep, and that this minimum scale decreases with increasing ϕE. Specifically, the ratio of Rsub2 to saturation deficit (1 − ϕE) must exceed a certain threshold value that depends on cloud-layer environmental lapse rate. Idealized, large-eddy simulations of moist convection forced by horizontally varying surface fluxes show strong sensitivity of maximum cumulus height to both ϕE and Rsub consistent with the hypothesis. Increasing Rsub by only 300–400 m can lead to a large increase (>5 km) in cloud height. A passive tracer analysis shows that the bulk fractional entrainment rate decreases rapidly with Rsub but depends little on ϕE. However, buoyancy dilution increases as either Rsub or ϕE decreases; buoyancy above the level of free convection is rapidly depleted in dry environments when Rsub is small. While deep convective initiation occurs with an increase in relative humidity of the near environment from moistening by earlier convection, the importance of this moisture preconditioning is inconclusive as it is accompanied by an increase in Rsub. Overall, it is concluded that small changes to Rsub driven by external forcing or by convection itself could be a dominant regulator of deep convective initiation.
    • Download: (3.672Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Statistics

      Influences of Environmental Relative Humidity and Horizontal Scale of Subcloud Ascent on Deep Convective Initiation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4285907
    Collections
    • Journal of the Atmospheric Sciences

    Show full item record

    date accessioned2022-05-09T00:56:29Z
    date available2022-05-09T00:56:29Z
    date copyright20 Jan 2022
    date issued2022
    identifier otherJAS-D-21-0056.1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285907
    description abstractThis study examines two factors impacting initiation of moist deep convection: free-tropospheric environmental relative humidity (ϕE) and horizontal scale of subcloud ascent (Rsub), the latter exerting a dominant control on cumulus cloud width. A simple theoretical model is used to formulate a “scale selection” hypothesis: that a minimum Rsub is required for moist convection to go deep, and that this minimum scale decreases with increasing ϕE. Specifically, the ratio of Rsub2 to saturation deficit (1 − ϕE) must exceed a certain threshold value that depends on cloud-layer environmental lapse rate. Idealized, large-eddy simulations of moist convection forced by horizontally varying surface fluxes show strong sensitivity of maximum cumulus height to both ϕE and Rsub consistent with the hypothesis. Increasing Rsub by only 300–400 m can lead to a large increase (>5 km) in cloud height. A passive tracer analysis shows that the bulk fractional entrainment rate decreases rapidly with Rsub but depends little on ϕE. However, buoyancy dilution increases as either Rsub or ϕE decreases; buoyancy above the level of free convection is rapidly depleted in dry environments when Rsub is small. While deep convective initiation occurs with an increase in relative humidity of the near environment from moistening by earlier convection, the importance of this moisture preconditioning is inconclusive as it is accompanied by an increase in Rsub. Overall, it is concluded that small changes to Rsub driven by external forcing or by convection itself could be a dominant regulator of deep convective initiation.
    titleInfluences of Environmental Relative Humidity and Horizontal Scale of Subcloud Ascent on Deep Convective Initiation
    typeJournal Paper
    journal volume79
    journal issue2
    journal titleJournal of the Atmospheric Sciences
    identifier doi10.1175/JAS-D-21-0056.1
    page337–359
    treeJournal of the Atmospheric Sciences:;2022:;volume( 079 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian