    Selection Methodology of Femoral Stems According to the Cross Section and the Maximum Stresses

    Source: Journal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 005::page 54502-1
    Author:
    López Galiano, Iván Camilo
    ,
    Juha, Mario
    ,
    Ortiz, Juan Guillermo
    ,
    Echeverry-Mejia, Julián
    DOI: 10.1115/1.4053006
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The maximum stresses on a femoral stem must be known for selecting the right size and shape of the shaft cross-sectional area for reducing the stress shielding effect generated after the total hip arthroplasty (THA) surgical procedure. The methodology proposed in this study provides the tools to the designers of femoral stems and orthopedic surgeons to select the adequate femoral stem cross section, decreasing the stiffness of the stem, thus reducing the stress shielding effect in the patient bones. The first contribution is the theoretical development of the maximum static stress calculation for 12 different femoral stem models with the beam theory, followed by the comparison with the static finite element analysis (FEA) simulations and finally the experimental corroboration of one femoral stem model measuring the strain with linear strain gages and transform it to stresses, the three different approaches provide comparable results, with a maximum average error of less than 8.5%. The second contribution is the formulation of a new selection methodology based on maximum stresses in the femoral stem and the cross section area for decreasing the stress shielding effect, optimizing the area needed for withstand the loads and decreasing the overall stiffens of the stem.
    • Download: (925.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Selection Methodology of Femoral Stems According to the Cross Section and the Maximum Stresses

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4285319
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorLópez Galiano, Iván Camilo
    contributor authorJuha, Mario
    contributor authorOrtiz, Juan Guillermo
    contributor authorEcheverry-Mejia, Julián
    date accessioned2022-05-08T09:35:09Z
    date available2022-05-08T09:35:09Z
    date copyright1/21/2022 12:00:00 AM
    date issued2022
    identifier issn0148-0731
    identifier otherbio_144_05_054502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285319
    description abstractThe maximum stresses on a femoral stem must be known for selecting the right size and shape of the shaft cross-sectional area for reducing the stress shielding effect generated after the total hip arthroplasty (THA) surgical procedure. The methodology proposed in this study provides the tools to the designers of femoral stems and orthopedic surgeons to select the adequate femoral stem cross section, decreasing the stiffness of the stem, thus reducing the stress shielding effect in the patient bones. The first contribution is the theoretical development of the maximum static stress calculation for 12 different femoral stem models with the beam theory, followed by the comparison with the static finite element analysis (FEA) simulations and finally the experimental corroboration of one femoral stem model measuring the strain with linear strain gages and transform it to stresses, the three different approaches provide comparable results, with a maximum average error of less than 8.5%. The second contribution is the formulation of a new selection methodology based on maximum stresses in the femoral stem and the cross section area for decreasing the stress shielding effect, optimizing the area needed for withstand the loads and decreasing the overall stiffens of the stem.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSelection Methodology of Femoral Stems According to the Cross Section and the Maximum Stresses
    typeJournal Paper
    journal volume144
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4053006
    journal fristpage54502-1
    journal lastpage54502-7
    page7
    treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian