    Investigation of the Effect of the Stages Number, the Impeller Outlet Width, and the Impeller Outlet Angle on the Performance of an Industrial Electric Submersible Pump

    Source: Journal of Fluids Engineering:;2022:;volume( 144 ):;issue: 008::page 81203-1
    Author:
    Firatoglu, Zeynel A.
    ,
    Alihanoglu, Mustafa N.
    DOI: 10.1115/1.4053652
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study has investigated the effect of the number of stages, the blade outlet spacing, and the blade outlet angle of a selected industrial submersible pump on the pump performance. The main steps in the study are outlined below: Firstly, the operating characteristics in different stages of a selected industrial submersible pump were measured by the experiment. Following the measurements, the effects of two basic geometric parameters, such as impeller outlet width and impeller outlet angle on the pump performance were examined with computational fluid dynamics (CFD) simulations verified by the experimental measurements. It was seen that the geometric parameters, which were considered in the simulations, changed the size of the time-dependent variables, but the flow structure did not. Another striking finding from the CFD simulations carried out is it has been observed that while geometric arrangements have a partial effect on the flow structure along with the pump, they cause a difference in the critical values on the basic variables that define pump performance, such as pressure.
    • Download: (3.342Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Investigation of the Effect of the Stages Number, the Impeller Outlet Width, and the Impeller Outlet Angle on the Performance of an Industrial Electric Submersible Pump

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4284861
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorFiratoglu, Zeynel A.
    contributor authorAlihanoglu, Mustafa N.
    date accessioned2022-05-08T09:12:42Z
    date available2022-05-08T09:12:42Z
    date copyright3/2/2022 12:00:00 AM
    date issued2022
    identifier issn0098-2202
    identifier otherfe_144_08_081203.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284861
    description abstractThis study has investigated the effect of the number of stages, the blade outlet spacing, and the blade outlet angle of a selected industrial submersible pump on the pump performance. The main steps in the study are outlined below: Firstly, the operating characteristics in different stages of a selected industrial submersible pump were measured by the experiment. Following the measurements, the effects of two basic geometric parameters, such as impeller outlet width and impeller outlet angle on the pump performance were examined with computational fluid dynamics (CFD) simulations verified by the experimental measurements. It was seen that the geometric parameters, which were considered in the simulations, changed the size of the time-dependent variables, but the flow structure did not. Another striking finding from the CFD simulations carried out is it has been observed that while geometric arrangements have a partial effect on the flow structure along with the pump, they cause a difference in the critical values on the basic variables that define pump performance, such as pressure.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInvestigation of the Effect of the Stages Number, the Impeller Outlet Width, and the Impeller Outlet Angle on the Performance of an Industrial Electric Submersible Pump
    typeJournal Paper
    journal volume144
    journal issue8
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4053652
    journal fristpage81203-1
    journal lastpage81203-13
    page13
    treeJournal of Fluids Engineering:;2022:;volume( 144 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian