    Development and Validation of a Finite Element Model of Wear in UHMWPE Liner Using Experimental Data From Hip Simulator Studies

    Source: Journal of Biomechanical Engineering:;2021:;volume( 144 ):;issue: 003::page 31001-1
    Author:
    Kottan, Nihal
    ,
    Gowtham, N. H.
    ,
    Basu, Bikramjit
    DOI: 10.1115/1.4052373
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The wear of acetabular liner is one of the key factors determining osseointegration and long-term performance of total hip joint replacement implants. The experimental measurements of wear in total hip replacement components are time and cost-intensive. While addressing this aspect, a finite element model of a hip joint bearing consisting of zirconia-toughened alumina femoral head and ultrahigh molecular weight polyethylene liner was developed to predict the dynamic wear response of the liner. The Archard–Lancaster equation, consisting of surface contact pressure, wear rate, and sliding distance, was employed to predict the wear of the acetabular liner. The contact pressure and wear at the articulating surface were found to decrease over time. A new computational method involving three-dimensional point clouds from the finite element analyzed results were used to construct wear maps. The model was able to predict the linear wear, over 2 × 106 cycles with relative errors ranging from 9% to 36% when compared to the published results. The increasing error percentage occurring primarily from the use of a constant wear rate was reduced to a maximum of 17% by introducing a correction factor. The volumetric rate was predicted with a maximum relative error of 7% with the implementation of the correction factor. When the model was implemented to study acetabular liners of diameters ranging from 28 to 36 mm, the linear wear was seen to decrease with an increase in femoral head diameter, which is in agreement with the clinical data. This study emphasizes the need to develop more such FEA-based computational studies to reliably predict and correlate with experimentally measured temporal evolution of wear of load-bearing articulating joints.
    • Download: (2.568Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development and Validation of a Finite Element Model of Wear in UHMWPE Liner Using Experimental Data From Hip Simulator Studies

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4284852
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorKottan, Nihal
    contributor authorGowtham, N. H.
    contributor authorBasu, Bikramjit
    date accessioned2022-05-08T09:12:10Z
    date available2022-05-08T09:12:10Z
    date copyright10/11/2021 12:00:00 AM
    date issued2021
    identifier issn0148-0731
    identifier otherbio_144_03_031001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284852
    description abstractThe wear of acetabular liner is one of the key factors determining osseointegration and long-term performance of total hip joint replacement implants. The experimental measurements of wear in total hip replacement components are time and cost-intensive. While addressing this aspect, a finite element model of a hip joint bearing consisting of zirconia-toughened alumina femoral head and ultrahigh molecular weight polyethylene liner was developed to predict the dynamic wear response of the liner. The Archard–Lancaster equation, consisting of surface contact pressure, wear rate, and sliding distance, was employed to predict the wear of the acetabular liner. The contact pressure and wear at the articulating surface were found to decrease over time. A new computational method involving three-dimensional point clouds from the finite element analyzed results were used to construct wear maps. The model was able to predict the linear wear, over 2 × 106 cycles with relative errors ranging from 9% to 36% when compared to the published results. The increasing error percentage occurring primarily from the use of a constant wear rate was reduced to a maximum of 17% by introducing a correction factor. The volumetric rate was predicted with a maximum relative error of 7% with the implementation of the correction factor. When the model was implemented to study acetabular liners of diameters ranging from 28 to 36 mm, the linear wear was seen to decrease with an increase in femoral head diameter, which is in agreement with the clinical data. This study emphasizes the need to develop more such FEA-based computational studies to reliably predict and correlate with experimentally measured temporal evolution of wear of load-bearing articulating joints.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment and Validation of a Finite Element Model of Wear in UHMWPE Liner Using Experimental Data From Hip Simulator Studies
    typeJournal Paper
    journal volume144
    journal issue3
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4052373
    journal fristpage31001-1
    journal lastpage31001-10
    page10
    treeJournal of Biomechanical Engineering:;2021:;volume( 144 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian