    Experimental Investigation of Local Heat Transfer Measurement Having Inclined Discrete Ribs of Solar Air Heater Duct Using LCT Technique

    Source: Journal of Thermal Science and Engineering Applications:;2021:;volume( 014 ):;issue: 002::page 21015-1
    Author:
    Rathor, Yogendra
    ,
    Aharwal, K. R.
    DOI: 10.1115/1.4052597
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The steady-state experiment using liquid crystal thermography has been conducted for the analysis of Nusselt number distribution over the absorber surface of solar air heater (SAH) duct having a gap with the staggered arrangement in inclined rib geometry to recuperate its thermal performance. The heat transfer experiment is performed with uniform heat flux and thermo-chromic liquid crystal (TLC) is utilized to show the temperature distribution profile over the ribbed surfaces of the rectangular duct of aspect ratio of 5. The colored pattern image of TLCs was acquired using a 3CCD (charged couple device) camera and exported to a Tagged Image File Format (TIFF) file format using frame grabbing SOFTWARE SAPERALT which was further processed to get hue, saturation, intensity (HSI) values. The flow parameters considered in this present investigation are Re, d/W, and g/e varied from 4000 − 12,500, 0.15 − 0.45, and 1 − 4, respectively. Experiments has been performed with fixed P/e, r/e, p′/P, α, and e/Dh of 10, 2, 0.6, 60 deg, and 0.0303, respectively. The influence of relative gap position and relative gap width on flow pattern has been analyzed. The maximum augmentation in Nu and f over the smooth duct was obtained as 4.01 and 4.28 times, respectively, at the optimum value of d/W = 0.35 and g/e = 2 under similar flow conditions. The maximum value of THPP obtained at d/W and g/e of 0.35 and 2, respectively, and Reynolds number of 12,445.
    • Download: (1.329Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental Investigation of Local Heat Transfer Measurement Having Inclined Discrete Ribs of Solar Air Heater Duct Using LCT Technique

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4284383
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorRathor, Yogendra
    contributor authorAharwal, K. R.
    date accessioned2022-05-08T08:49:12Z
    date available2022-05-08T08:49:12Z
    date copyright11/17/2021 12:00:00 AM
    date issued2021
    identifier issn1948-5085
    identifier othertsea_14_2_021015.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284383
    description abstractThe steady-state experiment using liquid crystal thermography has been conducted for the analysis of Nusselt number distribution over the absorber surface of solar air heater (SAH) duct having a gap with the staggered arrangement in inclined rib geometry to recuperate its thermal performance. The heat transfer experiment is performed with uniform heat flux and thermo-chromic liquid crystal (TLC) is utilized to show the temperature distribution profile over the ribbed surfaces of the rectangular duct of aspect ratio of 5. The colored pattern image of TLCs was acquired using a 3CCD (charged couple device) camera and exported to a Tagged Image File Format (TIFF) file format using frame grabbing SOFTWARE SAPERALT which was further processed to get hue, saturation, intensity (HSI) values. The flow parameters considered in this present investigation are Re, d/W, and g/e varied from 4000 − 12,500, 0.15 − 0.45, and 1 − 4, respectively. Experiments has been performed with fixed P/e, r/e, p′/P, α, and e/Dh of 10, 2, 0.6, 60 deg, and 0.0303, respectively. The influence of relative gap position and relative gap width on flow pattern has been analyzed. The maximum augmentation in Nu and f over the smooth duct was obtained as 4.01 and 4.28 times, respectively, at the optimum value of d/W = 0.35 and g/e = 2 under similar flow conditions. The maximum value of THPP obtained at d/W and g/e of 0.35 and 2, respectively, and Reynolds number of 12,445.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Investigation of Local Heat Transfer Measurement Having Inclined Discrete Ribs of Solar Air Heater Duct Using LCT Technique
    typeJournal Paper
    journal volume14
    journal issue2
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4052597
    journal fristpage21015-1
    journal lastpage21015-12
    page12
    treeJournal of Thermal Science and Engineering Applications:;2021:;volume( 014 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian