Modification of a Simplified Hip Joint Simulator Into an ISO 14242-1 Compliant Design and a Comparison of Wear Test ResultsSource: Journal of Tribology:;2021:;volume( 144 ):;issue: 005::page 51703-1DOI: 10.1115/1.4052942Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The ISO 14242-1 standard for hip joint simulator wear testing specifies a set of test conditions for the simulation of normal level walking in optimal conditions. Since some of the established simulators, such as the 12-station HUT-4, are not ISO 14242-1 compliant, the present study was carried out to answer the following question. Does wear produced in ISO 14242-1 conditions differ from that obtained earlier with the simplified HUT-4 hip joint simulator for similar specimens in normal level walking, optimal conditions? The established HUT-4 hip joint simulator was made ISO compliant by an implementation of a number of modifications. One of the modifications was the design and construction of a novel servo-electric load actuator with a proven dynamic response. The other modifications were related to the Euler sequence of motions, acetabular abduction angle, enclosure of the lubricant chamber, and temperature control. A 5 million-cycle wear test with thin, large-diameter VEXLPE liners resulted in a wear rate close to that obtained earlier with the HUT-4. The burnished bearing surface in both tests was in agreement with clinical retrieval studies. It appeared that a more simple, inexpensive hip joint simulator can reproduce clinical wear mechanisms. However, the simulator must meet certain basic requirements. The most important of these is likely to be the correct type of multidirectional relative motion, for which biaxial motion is sufficient. It is emphasized that the present study was not intended to show a similarity in wear produced by the ISO 14242-1 and HUT-4 wear test systems.
|
Collections
Show full item record
| contributor author | Saikko, Vesa | |
| contributor author | Morad, Omar | |
| contributor author | Viitala, Raine | |
| date accessioned | 2022-05-08T08:45:17Z | |
| date available | 2022-05-08T08:45:17Z | |
| date copyright | 11/25/2021 12:00:00 AM | |
| date issued | 2021 | |
| identifier issn | 0742-4787 | |
| identifier other | trib_144_5_051703.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4284298 | |
| description abstract | The ISO 14242-1 standard for hip joint simulator wear testing specifies a set of test conditions for the simulation of normal level walking in optimal conditions. Since some of the established simulators, such as the 12-station HUT-4, are not ISO 14242-1 compliant, the present study was carried out to answer the following question. Does wear produced in ISO 14242-1 conditions differ from that obtained earlier with the simplified HUT-4 hip joint simulator for similar specimens in normal level walking, optimal conditions? The established HUT-4 hip joint simulator was made ISO compliant by an implementation of a number of modifications. One of the modifications was the design and construction of a novel servo-electric load actuator with a proven dynamic response. The other modifications were related to the Euler sequence of motions, acetabular abduction angle, enclosure of the lubricant chamber, and temperature control. A 5 million-cycle wear test with thin, large-diameter VEXLPE liners resulted in a wear rate close to that obtained earlier with the HUT-4. The burnished bearing surface in both tests was in agreement with clinical retrieval studies. It appeared that a more simple, inexpensive hip joint simulator can reproduce clinical wear mechanisms. However, the simulator must meet certain basic requirements. The most important of these is likely to be the correct type of multidirectional relative motion, for which biaxial motion is sufficient. It is emphasized that the present study was not intended to show a similarity in wear produced by the ISO 14242-1 and HUT-4 wear test systems. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Modification of a Simplified Hip Joint Simulator Into an ISO 14242-1 Compliant Design and a Comparison of Wear Test Results | |
| type | Journal Paper | |
| journal volume | 144 | |
| journal issue | 5 | |
| journal title | Journal of Tribology | |
| identifier doi | 10.1115/1.4052942 | |
| journal fristpage | 51703-1 | |
| journal lastpage | 51703-8 | |
| page | 8 | |
| tree | Journal of Tribology:;2021:;volume( 144 ):;issue: 005 | |
| contenttype | Fulltext |