    Design and Preliminary Validation of Grasp Assistive Device for an Industrial Environment

    Source: Journal of Medical Devices:;2022:;volume( 016 ):;issue: 002::page 21002-1
    Author:
    Loewen, Daniel
    ,
    Chandrashekar, Naveen
    DOI: 10.1115/1.4052899
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Carpal tunnel syndrome and tendonitis are two common upper extremity cumulative trauma disorders (CTD) related to repetitive and forceful activities in industrial environments. Reducing the muscular force during activities such as the operation of a pistol grip hand tool could result in lower incidence of CTDs. The objective of this research was to reduce the muscular contribution to the grip force using an active grasp assist orthosis system. A novel soft, pneumatic grasp assistive device was designed to augment the users' strength during operation of pistol grip hand tool. The optimized design was fabricated using rapid prototyping. Device effectiveness was quantified by measuring muscle activity and grip force during an in vivo study of a common industrial activity. Nine subjects experienced with power tools employed by an automobile manufacturer installed 18 fasteners using a pistol grip DC tool with and without the grasp assistive device. Surface electromyography (sEMG) was used to measure the activity of four muscles commonly associated with grasping. The grasp assist significantly reduced the mean, combined, normalized muscle activity by 18% (p<
     
    0.05). Muscle activation results were contextualized using the revised strain index (RSI). The grasp assistive device trial yielded a significantly lower mean RSI value than the typical trial by 13% (p<
     
    0.05). Using an active grasp assist orthosis could reduce the incidence of CTDs in able bodied industrial workers using DC hand tools. The device used a unique design of sinusoidal bellows oriented at 45 deg to the plane of symmetry that yielded higher force output and a lower bending ratio and lower input pressure with acceptable device rigidity and strength.
     
    • Download: (2.691Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design and Preliminary Validation of Grasp Assistive Device for an Industrial Environment

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4283976
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorLoewen, Daniel
    contributor authorChandrashekar, Naveen
    date accessioned2022-05-08T08:28:53Z
    date available2022-05-08T08:28:53Z
    date copyright2/3/2022 12:00:00 AM
    date issued2022
    identifier issn1932-6181
    identifier othermed_016_02_021002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283976
    description abstractCarpal tunnel syndrome and tendonitis are two common upper extremity cumulative trauma disorders (CTD) related to repetitive and forceful activities in industrial environments. Reducing the muscular force during activities such as the operation of a pistol grip hand tool could result in lower incidence of CTDs. The objective of this research was to reduce the muscular contribution to the grip force using an active grasp assist orthosis system. A novel soft, pneumatic grasp assistive device was designed to augment the users' strength during operation of pistol grip hand tool. The optimized design was fabricated using rapid prototyping. Device effectiveness was quantified by measuring muscle activity and grip force during an in vivo study of a common industrial activity. Nine subjects experienced with power tools employed by an automobile manufacturer installed 18 fasteners using a pistol grip DC tool with and without the grasp assistive device. Surface electromyography (sEMG) was used to measure the activity of four muscles commonly associated with grasping. The grasp assist significantly reduced the mean, combined, normalized muscle activity by 18% (p<
    description abstract0.05). Muscle activation results were contextualized using the revised strain index (RSI). The grasp assistive device trial yielded a significantly lower mean RSI value than the typical trial by 13% (p<
    description abstract0.05). Using an active grasp assist orthosis could reduce the incidence of CTDs in able bodied industrial workers using DC hand tools. The device used a unique design of sinusoidal bellows oriented at 45 deg to the plane of symmetry that yielded higher force output and a lower bending ratio and lower input pressure with acceptable device rigidity and strength.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign and Preliminary Validation of Grasp Assistive Device for an Industrial Environment
    typeJournal Paper
    journal volume16
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4052899
    journal fristpage21002-1
    journal lastpage21002-9
    page9
    treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian